E11A102U012J Sanyo Denki
Wake Industrial LLC is not an authorized distributor of this product.
The Sanyo Denki E11A102U012J belongs to the SANUPS Power Supplies series and offers an output capacity of 1 kVA or 0.7 kW with a sine wave output waveform. It operates on a single-phase input voltage of 200 to 240 VAC and features a backup time of 5 minutes with a battery configuration of 2 x 12 V valve-regulated lead-acid batteries. The unit weighs 17 kilograms and has dimensions of 440 by 408 by 86 millimeters.
Internal Product Review
The E11A102U012J is a SANUPS power supply engineered for clean backup power, delivering 1 kVA / 0.7 kW output with a sine wave waveform. Single-phase, 2-wire input and 200/220/230/240 VAC compatibility support straightforward integration into standard industrial power systems. A small valve-regulated lead-acid battery system provides 5 minutes of backup time, making this unit a dependable choice for controlled shutdown support.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The E11A102U012J is a rack-mount uninterruptible power supply produced by Sanyo Denki for the SANUPS Power Supplies series. In factory automation panels, the unit continues supplying AC power to programmable controllers, fieldbus gateways, and safety relays when incoming power fails, preventing unexpected machine stops and data corruption. Its design integrates the inverter, charger, and maintenance-free battery into one chassis suitable for 19-inch equipment racks. By isolating sensitive control circuits from voltage dips and brief outages common during motor starts or utility transfer events, it stabilizes plant operation.
The supply draws up to 0.9 kVA from a single-phase, two-wire source and accommodates 200/220/230/240 VAC at 50/60 Hz through an IEC60320-C14 inlet connected to a NEMA L6-20P plug. A 10 A circuit breaker protects the upstream circuit against overload. Internally, the converter provides 1 kVA / 0.7 kW of continuous power and routes it to four IEC60320-C13 outlets. If utility power disappears, the battery sustains that load for 5 min, providing enough time for orderly shutdown sequences or an automatic switchover to a standby generator. That window also provides time for networked drives to disconnect from bus power without generating fault events.
Energy storage relies on a 2 × 12 V small valve-regulated lead-acid battery pack that delivers 68 W on a 15-minute discharge curve. The battery, charger, and control electronics share a low-profile steel housing measuring 440 × 408 × 86 mm. The installed weight is 17 kg, which keeps rack loading moderate. The sealed battery chemistry permits horizontal mounting and eliminates routine electrolyte inspections. The inverter produces a true sine wave, ensuring that downstream equipment receives clean voltage even while operating on battery power.