4.94 based on 222 reviews

🙶 Product was as advertised, got the machine back up and running at a fraction of OEM price. Delivered on ti... 🙷

3NF-16 Kollmorgen

In-Stock, Ships 3-5 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The 3NF-16 is a Kollmorgen mains EMI filter rated for 16 A with 480 VAC phase-to-phase capability. Low DC resistance of 3 x 8.24 mOhm at 25 °C and operation from -25 to +100 °C support efficient, dependable integration.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 3NF-16 is a single-stage mains EMI filter produced by Kollmorgen within the Mains EMI Filters series. Installed at the input of servo amplifiers, PLC cabinets, or variable-frequency drives, the device suppresses differential-mode and common-mode interference returning to the power grid. By reducing high-frequency noise, the filter helps machinery meet electromagnetic emission limits and prevents conducted disturbances from affecting neighboring control circuits, sensors, and communication buses that operate in the same industrial enclosure.

The filter has a rated through current of 16 A, so branch protection devices and upstream cabling must support that continuous load. Line-to-line voltage endurance is specified at 480 VAC, allowing direct connection to standard three-phase mains, while the line-to-ground rating of 275 VAC is the maximum permissible potential between a phase and protective earth. During normal service, the filter produces only 33 mA of displacement current at 400 VAC and 50 Hz, which helps prevent premature tripping of ground-fault monitoring equipment. A series resistance of 3 × 8.24 mΩ at 25 °C introduces negligible voltage drop, maintaining drive bus stability even under high surge demand.

The device is intended for panel spaces where the ambient temperature does not exceed 50 °C. Its internal components are qualified for continuous operation up to a maximum temperature of 100 °C. In safety analyses, the worst-case leakage current reaches 181.5 mA at 230 VAC and 50 Hz, so protective earth conductors must be sized for that condition. The housing measures 250 mm long and 45 mm wide, with a height of 70 mm, supporting DIN-rail or chassis mounting without obstructing adjacent modules. Dielectric integrity is confirmed by a phase-to-earth test pulse of 2.65 kVDC applied for 2 seconds.

Climatic Test Class
25/100/21
Dc Resistance
3 x 8.24 mOhm @ 25 °C
Height
70 mm
Max Operating Temp
+100 °C
Min Operating Temp
-25 °C
Operational Leakage
33 mA @ 400 VAC, 50 Hz
Overall Length
250 mm
Rated Ambient Temp
50 °C
Rated Current
16 A
Rated Voltage P-e
275 VAC
Rated Voltage P-p
480 VAC
Test Voltage P-e
2.65 kVDC, 2 s
Test Voltage P-p
2.1 kVDC, 2 s
Weight
0.8 kg
Width
45 mm
Worst-case Leakage
181.5 mA @ 230 VAC, 50 Hz

Frequently Asked Questions about 3NF-16:

Q: What is the rated current of the 3NF-16 EMI filter?

A: The 3NF-16 mains EMI filter is rated for continuous operation at up to 16 A.

Q: What is the maximum line-to-line operating voltage supported by the 3NF-16?

A: The highest rated voltage between line-to-line (P-p) for the 3NF-16 is 480 VAC.

Q: What is the temperature operating range for the 3NF-16?

A: This filter has a minimum operating temperature of -25 °C and a maximum of +100 °C.

Q: What is the operational leakage current for the 3NF-16 filter?

A: The typical operational leakage current is 33 mA at 400 VAC, 50 Hz.

Q: What is the DC resistance value for the 3NF-16 at room temperature?

A: The DC resistance of the 3NF-16 is 3 x 8.24 mOhm measured at 25 °C.

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo