The TTE-4503-1000-C-06 from Kollmorgen's Inland Direct Drive Motors operates with forced air cooling. It's rated at a power of 1.5 kW, boasts a 97% efficiency, and works within a voltage range of 200-240 V AC. Additionally, the motor has a frequency of 50/60 Hz, weighs 22 kg, and benefits from an IP54 protection class.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The TTE-4503-1000-C-06 torque motor offered by Kollmorgen has a maximum speed of 3000 RPM. The product has a torque rating of 44 lb-ft. This device encompasses windings on the outside of the frame case. The unit allows the installation of a resolver if needed to support its operation. It is highlighted by a compact and adaptable design. This motor helps in achieving high accuracy when its operating speed is very low because of its high resolution as well as coupling stiffness.
The product has a positional accuracy that is limited by an error-detecting transducer system. This device features no backlash associated with gear trains or coupling. The unit is a good choice for applications where commutation is not a limitation. It comes as three separate components that are integrated directly into the equipment where the motor has to be used. This motor may cause increased commutation arcing as its speed increases. The product may encounter a reduction in the torque per unit current permanently when the torque produced increases as a result of exceeding the rated current. This device is designed with its winding on the armature lamination stack and the keeper ring on the permanent magnet field assembly. The unit tends to portray degraded performance when the keeper ring is shifted or removed before the armature is inserted into the field. Its mounting surface must be mounted on a non-magnetic housing.
This torque motor develops a peak torque when the winding temperature is 25 degrees C and the rotor speed is zero at the stalled voltage. The product must be operated such that its thermal capacity limit is not exceeded. This device has a tolerance limit of +/-10% for its torque sensitivity. The unit should be handled by qualified personnel. Its DC resistance is the resistance between the terminals at 25 degrees C.
Frequently Asked Questions about TTE-4503-1000-C-06:
Q: When can the flux keepers of the TTE-4503-1000-C-06 motor be removed or loosened?
A: The flux keepers of the TTE-4503-1000-C-06 motor be removed or loosened only at the time of installation.
Q: How can the parts of the TTE-4503-1000-C-06 motor be protected against corrosion during extended storage?
A: The parts of the TTE-4503-1000-C-06 motor can be protected against corrosion during extended storage by putting them in a sealed plastic bag along with a desiccant for protection against excessive humidity.
Q: Where should the permanent magnet field assembly of the TTE-4503-1000-C-06 motor be inserted?
A: The permanent magnet field assembly of the TTE-4503-1000-C-06 motor should be inserted into its dedicated housing cavity.
Q: How can the keeper ring of the TTE-4503-1000-C-06 motor be removed during installation?
A: The keeper ring of the TTE-4503-1000-C-06 motor can be removed using a jackscrew during installation.
Q: How can the brush noise of the TTE-4503-1000-C-06 motor be eliminated?
A: The brush noise of the TTE-4503-1000-C-06 motor can be eliminated by connecting the cable points, amplifier, and preamplifier to a common ground.