AKT-AT-420-000

  • Rated 4.7 (6 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
  • Call for Expedited Shipping and Product Condition Options
The AKT-AT-420-000 is manufactured by Kollmorgen as part of their Advanced Kollmorgen Terminal series. It contains a Power Supply of 24 V DC via the power contacts and a Current Consumption Standard-bus of Typ. 20 mA. The AKT-AT-420-000 also has Pluggable wiring of For all Bus Terminals and an Electrical Isolation of 500 V rms.

Request a Quote Request Repair

Standard Repair Time is 1 - 2 weeks. 4 Day Rush Repair options are available.

AKT-AT-420-000

  • Rated 4.7 (6 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
  • Call for Expedited Shipping and Product Condition Options
The AKT-AT-420-000 is manufactured by Kollmorgen as part of their Advanced Kollmorgen Terminal series. It contains a Power Supply of 24 V DC via the power contacts and a Current Consumption Standard-bus of Typ. 20 mA. The AKT-AT-420-000 also has Pluggable wiring of For all Bus Terminals and an Electrical Isolation of 500 V rms.

Request a Quote Request Repair

Standard Repair Time is 1 - 2 weeks. 4 Day Rush Repair options are available.

Warranty
1 Year Wake Industrial Warranty Included
Shipping
Worldwide shipping via DHL, UPS, and Fedex
Repairs
Sell Us Your Surplus
Have a AKT-AT-420-000 to sell?
To Speak to a sales representative for pricing and lead time:

Product Description

The AKT-AT-420-000 is a four-channel analog output terminal. Manufactured by Kollmorgen automation, the AKT-AT-420-000 generates signals within the range of 0 to 20 mA. Power supply to the process level features a resolution of 12 Bits while it is electrically isolated. The output stage features a 24 Volts power supply, while the units four outputs feature 2-wire versions, with a common ground potential. The reference ground of the outputs is the 0 volts power contact. While the unit features a rated conversion time of ca. 4Milliseconds. The AKT-AT-420-000 comes with a current consumption from the standard bus rated at 20 mA (5V), while the current consumption from the power contacts is typically 40 mA (24 V).

The manufacturer recommends the surrounding environment meet the ambient temperature. During operation, the AKT-AT-420-000 ambient temperature is in the range of 0 degrees Celsius and 55 degrees Celsius. During transportation or storage, the ambient temperature is -25 to 85 degrees Celsius. The ambient relative humidity is 95% none condensing. The AKT-AT-420-000 comes with the IP-20 enclosure while the installation position is variable.

To ensure ease of operation status monitoring and aid in troubleshooting, the AKT-AT-420-000 comes with diagnostic LED indicators installed on the component. For safety reasons during the installation of the Bus Terminals on the mounting rails, the bus terminal system should first be brought into a safe and powered down state. This is whether carrying out the installation, disassembling the unit or while wiring the unit. The AKT-AT-420-000 supports an easy to use KAS integrated Development Environment.   

  • AKTAT420000
  • AKT AT 420 000
  • AKTAT-420-000

AKT-AT-420-000 Technical Specifications

:
Current Consumption Standard-bus: Typ. 20 mA
Electrical Isolation: 500 V rms
Pluggable wiring: For all Bus Terminals
Power Supply: 24 V DC via the power contacts