20.F5.MBR-Y0P1 KEB
Wake Industrial LLC is not an authorized distributor of this product.
The KEB 20.F5.MBR-Y0P1 is part of the F5 Combivert Axis Drives series and has a nominal input current of 83 Amps, supporting up to 50 horsepower motor power at 230V. This drive offers an output nominal current of 75 Amps, delivers up to 52 kVA, and is built with an IP20 protection rating for use in three-phase systems. It features a maximum main fuse rating of 100 Amps, maximum heat sink temperature of 90°C, and a relative humidity tolerance of 95% non-condensing.
Internal Product Review
The 20.F5.MBR-Y0P1 is a KEB F5 Combivert axis drive with 75 A output nominal current and 52 kVA nominal power. IP20 protection and EN 61800-3 EMC compliance support dependable cabinet integration in demanding industrial installations. A strong choice for higher-power motion systems requiring 50 HP motor capability.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 20.F5.MBR-Y0P1 is an inverter module manufactured by KEB for the F5 Combivert Axis Drives series. Its type code indicates inverter size 20 and a housing form factor marked R, which indicate the mechanical envelope and cooling path inside a control cabinet. Deployed on production lines, the drive converts fixed three-phase mains into variable frequency and voltage required for closed-loop motion control in pumps, extruders, or conveying equipment. By regulating torque and speed, it lets a PLC coordinate multiple axes without mechanical gear changes.
Designed for a three-phase supply, the unit accepts a nominal input current of 83 A and provides a nominal output current of 75 A, delivering 52 kVA to the motor. The power section supports up to 50 hp at 230 V, and the same power limit applies at higher mains voltage. Internal losses of 900 W must be removed through the rear heat sink. Protection against foreign objects is provided by the IP20 enclosure, while compliance with EN 61800-3 keeps conducted and radiated emissions within industrial limits. If load surges raise the current to 135 A, the drive trips to help prevent device failure, and Category 3K3 covers operation in switching rooms where temperature and humidity vary within normal industrial ranges.
The recommended mains fuse is 100 A, and power terminals must be tightened to 6 Nm to maintain contact integrity. The heat sink temperature must not exceed 90 °C; above that point, the control board initiates derating. Shielded motor cable runs can extend to 50 m when a 35 mm² conductor is used, allowing the inverter to be mounted remotely from the motor without excessive voltage drop. Operation is permitted up to 95% non-condensing relative humidity, and an internal current sensor monitors the 135 A trip point to protect both the output stage and connected machinery.