14.F5.C3D-YG1A KEB
Wake Industrial LLC is not an authorized distributor of this product.
The KEB 14.F5.C3D-YG1A is part of the F5 Combivert Axis Drives series and supports up to 10 HP of motor power. It features an input rated current of 23 Amps at 400 Volts and provides an output rated current of 16.5 Amps with an output rated power of 11 kVA. The drive includes a braking transistor and EMI filter as installed accessories and has a maximum heat sink temperature of 90 degrees Celsius.
Internal Product Review
The 14.F5.C3D-YG1A is a KEB F5 Combivert axis drive equipped with an integrated braking transistor and EMI filter, a highly practical configuration for controlled industrial installations. Rated for 400 V input and 16.5 A output current, the drive delivers confident performance and stands out as a strong choice for precise axis control.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 14.F5.C3D-YG1A inverter is manufactured by KEB as part of the F5 Combivert Axis Drives series. Classified under inverter size code 14, the unit includes an integrated braking transistor and an EMI filter, which reduce the need for separate external hardware, handle regenerated energy during deceleration, and help limit conducted interference on the supply lines. It is intended for automated machinery where closed-loop regulation of speed and torque supports stable axis motion, repeatable speed changes, and consistent response in positioning or conveying tasks.
The drive’s mains side accepts a three-phase supply at 400 V with a continuous input of 23 A, protected by a 25 A main fuse for upstream circuit protection. Internally, that energy is converted into an output capability of 11 kVA and 16.5 A rms at the motor terminals, enabling the specified 10 HP rating at 50/60 Hz and during 230 V Unit B operation. A 10 VDC reference source is available for external potentiometers, and the 24 V encoder and logic rail can supply 100 mA for feedback devices or sensors that need low-power auxiliary voltage. Thermal monitoring limits operation to a heat-sink temperature of 90 °C to help prevent derating and protect the power section during continuous use.
For transient loads, the inverter can deliver 29.7 A for short periods before the electronic current limit engages, while a hardware overcurrent trip activates at 35.6 A to protect the IGBTs from excessive stress. Control resolution is matched to modern PLC requirements: the analog outputs are pulse-width modulated at 3.4 kHz with 12-bit depth, and the analog inputs provide 11-bit resolution with a 2 ms scan time for responsive reference processing. Digital inputs present a 2.1 kΩ impedance, allowing direct connection to sourcing or sinking field devices without excessive loading. That combination allows the drive to process reference signals and field states without heavily loading connected devices during normal operation.