13.F5.GID-YP10 KEB
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The KEB 13.F5.GID-YP10 belongs to the F5 Combivert Axis Drives series and is rated for input voltages of 400 V and input currents of 17 A. This axis drive handles a maximum motor power of 7.5 HP and a rated output power of 8.3 kVA. It supports three-phase input, a rated output current of 12 A, and reaches a maximum heat sink temperature of 90 °C.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 13.F5.GID-YP10 is an AC axis drive from KEB’s F5 Combivert Axis Drives series. It sits between a three-phase supply and a matched motor to regulate output frequency and voltage. That control lets packaging, material-handling, and process equipment manage torque, speed, and direction with stable motor response.
This model supports motors up to 7.5 HP, which defines the mechanical load the inverter can propel without derating. Its mains terminals accept 400 V nominal line voltage and draw a rated input current of 17 A, so upstream protection and conductor sizing can be selected correctly. The power stage provides 8.3 kVA of apparent output, and the switching frequency is set to 4 kHz to balance audible noise with thermal demand.
For short transients, the drive can deliver 21.6 A before current limiting intervenes. Pulse-width modulation can be increased to 16 kHz when an application needs finer speed resolution. The heat sink may rise to 90 °C before thermal protection acts, and the unit also uses three input phases, a 25 A maximum mains fuse, a 25.9 A overcurrent trip, a 6 Hz minimum full-load frequency, and motor cable up to 4 mm² for safe panel integration.
Wake Industrial can arrange same-day shipping for urgent orders. Every purchase includes a 1-year warranty. Customers can use the chat tool available on the website for questions about fault codes, type codes, or general specifications, and the service is useful when quick clarification is needed before comparing options for a repair, replacement, or scheduled maintenance purchase to reduce downtime during replacement planning stages.
Frequently Asked Questions about 13.F5.GID-YP10:
Q: What is the maximum motor power supported by the 13.F5.GID-YP10 drive at 230V?
A: The 13.F5.GID-YP10 is capable of handling a maximum motor power of 7.5 HP when used with 230V in Unit B configuration.
Q: What is the rated input voltage requirement for the 13.F5.GID-YP10 drive?
A: This model operates with a rated input voltage of 400 V for industrial applications.
Q: What is the highest switching frequency supported by the 13.F5.GID-YP10?
A: The maximum switching frequency of this drive reaches up to 16 kHz for efficient motor control.
Q: What is the maximum main fuse rating for the 13.F5.GID-YP10 from the F5 Combivert series?
A: The 13.F5.GID-YP10 can accommodate up to 25 A as the maximum main fuse rating.
Q: Is an encoder feedback card included in the 13.F5.GID-YP10 drive upon factory delivery?
A: No encoder feedback card is installed at the factory for this model.