12.F5.CBD-YA50 KEB
Wake Industrial LLC is not an authorized distributor of this product.
The KEB 12.F5.CBD-YA50 is part of the F5 Combivert Axis Drives series and features a 400 V AC/DC input supply with an inverter size code of 12. It has 2 analog inputs, 8 digital inputs, 2 relay outputs, and supports a general maximum motor power of 5 HP. The drive offers a maximum output frequency of 800 Hz and operates with a carrier frequency of 8 kHz.
Internal Product Review
The 12.F5.CBD-YA50 is a KEB F5 Combivert axis drive designed for 400 V AC/DC input and 5 HP motor applications. A 2 ms control scan time and 800 Hz max output frequency make this unit especially appealing for fast, precise motion control. Eight digital inputs and 29 control terminals add valuable flexibility for streamlined system integration.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 12.F5.CBD-YA50 is an axis drive module from KEB that belongs to the F5 Combivert Axis Drives series. Designed as a variable-frequency inverter, it regulates three-phase induction or synchronous motors used in conveyors, packaging machines, and positioning axes. By modulating DC-link energy into controlled AC output, the unit executes speed and torque commands supplied by a PLC. It integrates power conversion and basic I/O within a single enclosure for general-purpose industrial automation.
It has an input rating of 400 V AC/DC and uses a standard carrier frequency of 8 kHz, balancing acoustic noise with switching losses. The inverter can produce output frequencies up to 800 Hz, allowing compatible motors to operate far above the mains frequency in high-speed spindle applications. Field wiring terminates on 29 control terminals that distribute eight digital inputs, two analog inputs, two analog outputs, two relay outputs, and two transistor outputs to external sensors or actuators. Drive protection includes an overcurrent trip threshold of 216% of rated current, allowing the drive to clear severe faults before they damage the power stage. Parameter storage accommodates eight independent sets, allowing operating data for multiple machine configurations to reside in the same module.
The internal gate pattern can operate at 16 kHz, reducing stator vibration on noise-sensitive machinery. The power stage tolerates a short-term overload of 180% of rated load to handle rapid torque demands during acceleration. The control logic completes each processing cycle in 2 ms, synchronizing pulse-width modulation updates with feedback at elevated speeds. An encoder card is not installed, so position or speed sensors must connect through the native control terminals when the application requires external feedback. Classified under inverter size code 12, the module can drive motors rated up to 5 HP. Its standard cooling arrangement removes heat from the power electronics during operation and helps keep semiconductor temperatures within their permitted operating range.