4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

10.56.20B-1229 KEB

Available, Ships in 1-2 weeks
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The 10.56.20B-1229 is a KEB F5 Combivert frequency inverter designed for three-phase AC motor applications. UVW encoder feedback and TTL auxiliary signal output support clean signal handling and dependable axis control. The 400 V class and 3 HP motor capacity make the drive a strong fit for compact motion systems.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

KEB manufactures the 10.56.20B-1229 as part of its F5 Combivert Axis Drives series. The compact drive controller modulates the speed of asynchronous and synchronous machinery used in industrial automation. By converting fixed mains voltage into a variable output, it lets production equipment match motor speed to process demand, improving accuracy and limiting mechanical stress. This variable output also supports controlled acceleration and deceleration, reducing abrupt changes in motor speed during automated operating cycles.

The drive belongs to the 400 V voltage class, so it connects directly to standard three-phase factory supplies without an isolation transformer. It can energize motors up to 3 HP, which represents the maximum continuous shaft power the inverter can deliver under nominal ambient conditions. The unit is configured as a frequency inverter, producing a pulse-width-modulated output for closed-loop or open-loop speed regulation. Dynamic stopping energy is routed to an external resistor through terminals PA and PB, helping prevent DC-bus overvoltage during rapid deceleration. For applications that require position feedback, an incremental encoder can connect to the dedicated UVW interface, allowing commutation and speed monitoring across the operating range. The feedback connection provides the drive with rotor movement data needed for applications that require more precise motor regulation.

A programmable auxiliary output provides logic-level status at the TTL threshold, enabling a PLC to read fault or ready signals without additional interface hardware. The motor cables connect to terminals U, V, and W, using a conventional three-phase layout that simplifies field wiring and service access. The drive is compatible with a three-phase AC motor, supporting stable vector or V/Hz control across the load curve. Mechanical integration is guided by housing form factor code B, and the enclosure depth aligns with cabinets that use the same Combivert size matrix. Inverter size code 10 groups the unit with drives that share the same heat sink capacity and mounting-hole pattern. These common physical characteristics allow consistent cabinet spacing and mounting arrangements across compatible Combivert installations.

Auxiliary Signal Output Type
TTL
Braking Resistor Terminal
PA, PB
Drive Type
Frequency Inverter
Encoder Interface
UVW
General Max Motor Power (HP)
3
Housing Form Factor Code
B
Inverter Size Code
10
Motor Output Terminals
U, V, W
Motor Type
Three-Phase AC Motor
Voltage Class
400 V

Frequently Asked Questions about 10.56.20B-1229:

Q: What voltage class does the 10.56.20B-1229 KEB frequency inverter support?

A: The 10.56.20B-1229 drive supports a voltage class of 400 V for operation.

Q: What type of motor does the 10.56.20B-1229 frequency inverter operate?

A: This frequency inverter is designed for use with three-phase AC motors.

Q: What is the maximum motor power supported by the 10.56.20B-1229?

A: The drive provides a general maximum motor power rating of 3 horsepower.

Q: What type of auxiliary signal output does the 10.56.20B-1229 feature?

A: The auxiliary signal output on this model uses TTL logic levels.

Q: Which terminals are designated for the braking resistor on the 10.56.20B-1229 drive?

A: The braking resistor for the 10.56.20B-1229 should be connected to the PA and PB terminals.