The KEB 07.58.200-1229 is part of the F5 Combivert Axis Drives series and has a maximum motor power of 0.75 kW with a rated output current of 4.5 Amps. This drive operates with a 200 Volt input, uses a UVW encoder interface, and is rated at IP20 for protection. It allows a maximum mounting altitude of 3000 meters and supports auxiliary signal output type TTL.
Internal Product Review
The 07.58.200-1229 is a KEB F5 Combivert axis drive with a 200 V input class and 1-phase supply. Rated output current of 4.5 A and output frequency up to 408 Hz support precise, responsive motor control. IP20 protection makes this unit a strong choice for controlled industrial panels.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 07.58.200-1229 inverter is manufactured by KEB and belongs to the F5 Combivert Axis Drives series. This component serves as a dedicated speed and torque controller for a single motor axis in automated machinery. By converting fixed mains power into a regulated output, the drive allows precise adjustment of motor frequency for positioning, conveying, and process-control applications. Its regulated output also helps the connected motor respond consistently to changes in speed and torque commands.
The drive accepts a single-phase supply and has an input voltage class of 200 V, allowing connection to common plant mains. Its power stage switches at 4 kHz, balancing audible noise with heat generation. Continuous service is supported by an apparent power rating of 1.8 kVA and an output phase current of 4.5 A, making the unit suitable for motors within its operating range. The output frequency can reach 408 Hz, so the unit can control high-speed spindles as well as standard 50 or 60 Hz machinery. The analog command port uses a 0–10 V reference signal and draws 6 mA. Feedback is accepted through a UVW encoder interface, and a TTL auxiliary signal supports incremental monitoring. A 0.4 A control fuse protects the logic circuitry, while a 10 A intermediate fuse isolates the DC link. Two open-collector outputs can switch 30 V at 30 mA for status signaling.
The housing has an IP20 protection rating, so the inverter must be installed inside a suitable protective cabinet. The supported motor output reaches 0.75 kW, matching the available current and apparent power. Reliable operation is supported at altitudes up to 3000 m and in atmospheres with as much as 95% noncondensing humidity. These operating limits permit use on light-duty axes in humid plants or high-elevation facilities when the cabinet provides adequate ventilation. Sufficient clearance around the inverter allows heat to leave the enclosure and helps the power stage remain within its permitted temperature range.