4.94 based on 222 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

09.F0.R13-3429 KEB

In-Stock, Ships 3-5 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The 09.F0.R13-3429 is a KEB F0 Combivert control cabinet with IP20 protection and a vertical mounting format that suits clean panel installations well. A maximum output frequency of 408 Hz and allowable relative humidity up to 95% make this unit a strong technical choice for stable control performance.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 09.F0.R13-3429 is a control cabinet module manufactured by KEB for the F0 Combivert Control Cabinets series. It houses the drive and interface electronics that regulate motor speed and process signals. This arrangement allows power conversion and control functions to be centralized inside a protected enclosure for automated machinery.

A 0.4 A time-delay fuse protects the internal low-voltage control circuits from sustained overloads while allowing brief inrush currents without interrupting operation. The cabinet can generate carrier frequencies up to 408 Hz, enabling it to feed high-speed induction or permanent-magnet motors without saturating the magnetic circuit. Its enclosure carries an IP20 rating, which prevents accidental finger contact with live parts but requires installation inside a larger panel in dusty or wet environments. The unit weighs 3 kg, reducing the mechanical load on slide rails, mounting surfaces, and cabinet hinges. The electronics tolerate ambient relative humidity up to 95%, provided condensation does not occur inside the enclosure.

The reference inputs connect to upstream PLC analog modules. The first current command input has an impedance of 500 Ω, while the corresponding voltage input has an impedance of 56 kΩ; these values minimize loading errors on typical 0–20 mA or 0–10 V transmitters. A second channel is available with respective current and voltage input impedances of 250 Ω and 4.4 kΩ, supporting an additional speed or torque setpoint. The cabinet uses a vertical mounting orientation so convection can remove heat without forced fans. Installation requires 50 mm of clearance at the sides and 100 mm of clearance above and below to prevent neighboring equipment from obstructing airflow. These spaces also provide access to the terminals during installation and routine service.

Control Circuit Fuse
0.4 A Time-Lag
Max Output Frequency
408 Hz
Max Relative Humidity
95%
Mounting Orientation
Vertical
Protection Rating
IP20
Rack Unit Weight
3 kg
Ref Current Input Impedance
500 Ω
Ref Voltage Input Impedance
56 kΩ
Ref2 Current Input Impedance
250 Ω
Ref2 Voltage Input Impedance
4.4 kΩ
Side Clearance
50 mm
Top-bottom Clearance
100 mm

Frequently Asked Questions about 09.F0.R13-3429:

Q: What fuse rating is used for the control circuit in the 09.F0.R13-3429?

A: The control circuit fuse on the 09.F0.R13-3429 is rated at 0.4 A time-lag.

Q: What is the maximum output frequency for the 09.F0.R13-3429 control cabinet?

A: This model supports a maximum output frequency of 408 Hz.

Q: What is the recommended mounting orientation for the 09.F0.R13-3429?

A: The 09.F0.R13-3429 is designed for vertical mounting.

Q: What protection rating does the 09.F0.R13-3429 cabinet offer?

A: The protection rating for this unit is IP20.

Q: What is the maximum relative humidity permitted for operating the 09.F0.R13-3429?

A: The control cabinet can operate in environments with a maximum relative humidity of 95%.