09.F0.R13-3429 KEB
Wake Industrial LLC is not an authorized distributor of this product.
The KEB 09.F0.R13-3429 is part of the F0 Combivert Control Cabinets series and has a protection rating of IP20. This cabinet should be mounted vertically and has a rack unit weight of 3 kilograms. It includes a 0.4 amp time-lag control circuit fuse and supports a maximum output frequency of 408 Hz.
Internal Product Review
The 09.F0.R13-3429 is a KEB F0 Combivert control cabinet with IP20 protection and a vertical mounting format that suits clean panel installations well. A maximum output frequency of 408 Hz and allowable relative humidity up to 95% make this unit a strong technical choice for stable control performance.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 09.F0.R13-3429 is a control cabinet module manufactured by KEB for the F0 Combivert Control Cabinets series. It houses the drive and interface electronics that regulate motor speed and process signals. This arrangement allows power conversion and control functions to be centralized inside a protected enclosure for automated machinery.
A 0.4 A time-delay fuse protects the internal low-voltage control circuits from sustained overloads while allowing brief inrush currents without interrupting operation. The cabinet can generate carrier frequencies up to 408 Hz, enabling it to feed high-speed induction or permanent-magnet motors without saturating the magnetic circuit. Its enclosure carries an IP20 rating, which prevents accidental finger contact with live parts but requires installation inside a larger panel in dusty or wet environments. The unit weighs 3 kg, reducing the mechanical load on slide rails, mounting surfaces, and cabinet hinges. The electronics tolerate ambient relative humidity up to 95%, provided condensation does not occur inside the enclosure.
The reference inputs connect to upstream PLC analog modules. The first current command input has an impedance of 500 Ω, while the corresponding voltage input has an impedance of 56 kΩ; these values minimize loading errors on typical 0–20 mA or 0–10 V transmitters. A second channel is available with respective current and voltage input impedances of 250 Ω and 4.4 kΩ, supporting an additional speed or torque setpoint. The cabinet uses a vertical mounting orientation so convection can remove heat without forced fans. Installation requires 50 mm of clearance at the sides and 100 mm of clearance above and below to prevent neighboring equipment from obstructing airflow. These spaces also provide access to the terminals during installation and routine service.