26.DR.B28-1141 KEB

Ask for Availability

Current response time:
6 Minutes 40 Seconds

Preparing your secure checkout page...

The KEB 26.DR.B28-1141 is an input choke from the DR Motor Input Chokes series and supports 3-phase, 400 V input with a nominal current of 270 Amps. The choke features an inductance of 0.11 millihenry, a power loss of 290 Watts, and a conductor cross-section of 240 mm². Its dimensions are 395 mm in height, 352 mm in width, 230 mm in depth, and it weighs 37 kilograms.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 26.DR.B28-1141 motor input choke is produced by KEB within the DR Motor Input Chokes series. This three-phase reactor is wired on the line side of an AC drive, where it forms an L-filter with the supply impedance. It smooths current, suppresses transients, and reduces the total harmonic distortion fed back into the plant power network. By moderating electrical disturbances, the choke helps protect connected equipment and supports the reliable operation of sensitive automation devices on the same bus.

The choke has an inductance of 0.11 mH, which provides the reactance needed to reduce current ripple at the line frequency. It carries a nominal load of 270 A, allowing it to serve large drives without magnetic saturation under normal operating conditions. The coil has a nominal system voltage of 400 V, matching a common industrial power supply. During rated operation, the voltage drop equals 4% of the applied line voltage. This short-circuit impedance limits inrush current and keeps fault currents within predictable levels. Combined core and copper losses are 290 W, and the resulting heat must be considered when providing enclosure ventilation.

The copper bus bars accept cables with conductor cross sections up to 240 mm², providing capacity for the choke’s rated current. A threaded protective earth connection is provided by an M8 stud. The choke is 352 mm wide, 230 mm deep, and 395 mm high, allowing it to fit in deep floor-mounted cabinets while retaining suitable clearance for airflow. Its laminated steel core and wound conductors give it a mass of 37 kg, and integrated lifting points assist with handling during installation. Mounting uses 7 × 12 mm slotted holes arranged on centers measuring 249 × 82 mm, allowing the unit to be fastened directly to a backplate without additional brackets.

Conductor Cross-section
240 mm²
Depth
230 mm
Height
395 mm
Inductance
0.11 mH
Input Phases
3-phase
Input voltage
400 V
Mounting Centers
249 x 82 mm
Mounting Slot
7 x 12 mm
Nominal Current
270 A
Pe Terminal
M8
Power loss
290 W
Short-circuit Voltage
4%
Weight
37 kg
Width
352 mm

Frequently Asked Questions about 26.DR.B28-1141:

Q: What is the nominal current rating of the 26.DR.B28-1141 input choke?

A: The 26.DR.B28-1141 motor input choke is rated for a nominal current of 270 A, supporting high-power three-phase systems.

Q: What is the inductance value of the 26.DR.B28-1141 choke?

A: This model provides an inductance of 0.11 mH, contributing to effective reduction of electrical noise and harmonics.

Q: What input voltage is supported by the 26.DR.B28-1141 input choke?

A: The 26.DR.B28-1141 features an input voltage specification of 400 V for three-phase applications.

Q: What conductor cross-section is specified for the 26.DR.B28-1141?

A: This KEB input choke comes with a conductor cross-section of 240 mm² to accommodate large current capacities.

Q: How much power loss does the 26.DR.B28-1141 input choke have?

A: The power loss for this input choke is rated at 290 W, indicating the energy dissipated during operation.


Internal Product Review

  • ‘‘The 26.DR.B28-1141 is a KEB DR motor input choke designed for 3-phase 400 V drive systems. A 0.11 mH inductance and 270 A nominal current support stable line conditioning in high-demand installations.’’