4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

FC-102P7K5T4E20H1XGXXXXSXXXX Danfoss

Available
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The FC-102P7K5T4E20H1XGXXXXSXXXX is a Danfoss VLT FC 102 HVAC drive designed for three-phase power on 380 - 480 VAC systems. IP20 / Chassis protection and an RFI Class A1/B (C1) filter support clean cabinet integration and dependable operation in HVAC panels. A graphical local control panel and standard cabinet mounting make the drive a strong choice for efficient HVAC installations.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-102P7K5T4E20H1XGXXXXSXXXX is an AC variable-frequency drive produced by Danfoss for the VLT FC 102 HVAC Drives series. Installed inside air-handling or pump cabinets, it modulates motor speed so building automation systems can respond to actual airflow, pressure, or temperature demands instead of running motors at a fixed line frequency. By adjusting the electrical frequency supplied to the motor, the unit reduces energy consumption and mechanical wear in commercial and industrial HVAC systems. It can control equipment such as supply fans, exhaust fans, cooling tower fans, circulation pumps, and other variable-torque loads.

This drive accepts a three-phase supply range of 380–480 VAC, covering common 400 V and 480 V power systems without transformer tap changes. Its input section uses three-phase power, providing balanced loading across the phase conductors. Cabinet installation is supported by standard cable entries that accommodate typical metric gland plates. The enclosure provides IP20 chassis protection, so the drive must be mounted inside a suitable ventilated panel that prevents unintended contact with internal components. Conducted emissions are limited by an integrated RFI Class A1/B (C1) filter, allowing the unit to operate near sensitive control electronics when installed correctly. Users interact with the drive through a graphical local control panel that displays operating speed, current, settings, and fault information. The removable keypad also supports parameter transfer between compatible units. Standard cabinet mounting is available for A, B, or C frame sizes, and the factory mechanical interfaces remain unchanged because Adaptation B is not applied.

For applications that do not require regenerative braking, the power section has no brake chopper. Braking requirements must therefore be handled by the connected load or by suitable external equipment. The control section contains uncoated printed circuit boards, making the drive appropriate for clean, filtered indoor environments where moisture and corrosive contaminants are controlled. A standard language pack provides multilingual text on the display for setup, monitoring, and fault review. The drive does not include a mains disconnect or an integrated harmonic-mitigation option. External isolation, protection, and any required harmonic-control equipment must be selected to suit the connected electrical system and local installation requirements.

Adaptation A
Standard Cable Entries
Adaptation B
No adaptation
Brake - Safe Stop
No brake chopper
Coating PCB
Not coated PCB
LCP
Graphical Loc. Cont. Panel
Mains Option
No Mains Option
Mains Voltage
380 - 480 VAC
Mounting
Normal cabinet mounting A, B, C Frames
Power Phase
Three Phase Power
Product Group
VLT HVAC Drive
Protection Level
IP20 / Chassis
RFI Filter
RFI Class A1/B (C1)
Series Identifier
102
Software Language Pack
Standard Language Pack
Software Release
Latest release std. SW.

Frequently Asked Questions about FC-102P7K5T4E20H1XGXXXXSXXXX:

Q: What is the supported mains voltage range for the FC-102P7K5T4E20H1XGXXXXSXXXX drive?

A: The FC-102P7K5T4E20H1XGXXXXSXXXX is designed for operation on 380 - 480 VAC mains voltage.

Q: What phase configuration does the FC-102P7K5T4E20H1XGXXXXSXXXX require?

A: This drive supports three phase power input for industrial HVAC applications.

Q: What protection level is offered by the FC-102P7K5T4E20H1XGXXXXSXXXX drive?

A: The FC-102P7K5T4E20H1XGXXXXSXXXX provides a protection level of IP20 and comes in a chassis format.

Q: Does the FC-102P7K5T4E20H1XGXXXXSXXXX come with a local control panel?

A: A graphical local control panel (LCP) is included for user-friendly on-site configuration and monitoring.

Q: What RFI filter classification does the FC-102P7K5T4E20H1XGXXXXSXXXX have?

A: This drive includes an RFI filter rated at Class A1/B (C1) for electromagnetic compatibility.

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo