The Danfoss FC-102P4K0T4P55H1XGXXXXSXXXXAXBXCXXXXDX is part of the VLT FC 102 HVAC Drives series and supports a mains voltage of 380 to 480 VAC for three phase power. This model features an IP55 / Type 12 backplate for protection and includes a graphical local control panel. The drive also includes an RFI Class A1/B filter and standard cable entries.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-102P4K0T4P55H1XGXXXXSXXXXAXBXCXXXXDX is an AC variable frequency drive manufactured by Danfoss within the VLT FC 102 HVAC Drives series. It converts fixed-frequency mains power into a modulated output that matches the operating demands of fans, pumps, and compressors. This speed regulation allows building automation systems to control airflow, temperature, and pressure more precisely than mechanical throttling methods. Adjusting motor speed to actual demand can also reduce energy consumption and limit wear on dampers, valves, belts, and other connected components.

The enclosure has an IP55 / Type 12 backplate rating, protecting the internal electronics from dust and low-pressure water jets when the drive is installed correctly. Its input terminals accept a 380–480 VAC supply, making the drive suitable for common commercial and industrial power networks. The power section uses three-phase power to operate compatible HVAC motors with balanced phase loading. A front-mounted graphical local control panel provides access to parameters, operating data, and local start-and-stop controls without requiring a separate interface. Conducted emissions are limited by an integrated RFI Class A1/B (C1) filter, which supports operation on electrical networks that require electromagnetic interference control. The local display also presents drive status and fault information in a readable format for routine operation and troubleshooting.

The unit uses a Frame A5, B, and C backplate for an open drive back, allowing the heat sink to mount against a suitable cabinet surface for effective thermal transfer. The drive has no brake chopper, so it cannot control an external braking resistor through an integrated braking circuit. Deceleration settings must therefore remain within the drive and motor system’s available stopping capability to prevent excessive DC-bus voltage. The control board has an uncoated PCB, making installation in a clean, dry, and noncorrosive location important for dependable operation. Its interface includes the Standard Language Pack, providing the standard multilingual menu options available for this configuration. Cable routing, ventilation clearance, and mounting orientation should follow the applicable installation requirements so heat can leave the enclosure without obstruction.

A Option
No A Option
Adaptation A
Standard Cable Entries
Adaptation B
No adaptation
B Option
No B Option
Brake - Safe Stop
No brake chopper
C Option Software
No software option
C0 Option MCO
No C0 option
C1 Option
No C1 option
Coating PCB
Not coated PCB
D Option
No D option
LCP
Graphical Loc. Cont. Panel
Mains Option
No Mains Option
Mains Voltage
380 - 480 VAC
Mounting
Frame A5, B & C Backplate for open Drive back
Power Phase
Three Phase Power
Product Group
VLT HVAC Drive
Protection Level
IP55 / Type12 Backplate
RFI Filter
RFI Class A1/B (C1)
Series Identifier
102
Software Language Pack
Standard Language Pack
Software Release
Latest release std. SW.

Frequently Asked Questions about FC-102P4K0T4P55H1XGXXXXSXXXXAXBXCXXXXDX:

Q: What mains voltage does the FC-102P4K0T4P55H1XGXXXXSXXXXAXBXCXXXXDX HVAC drive support?

A: This drive operates with a mains voltage range of 380 to 480 VAC, making it suitable for standard industrial power supplies.

Q: Does the FC-102P4K0T4P55H1XGXXXXSXXXXAXBXCXXXXDX support single-phase or three-phase power?

A: The FC-102P4K0T4P55H1XGXXXXSXXXXAXBXCXXXXDX is designed for three-phase power systems.

Q: What is the protection level of the FC-102P4K0T4P55H1XGXXXXSXXXXAXBXCXXXXDX drive?

A: It features IP55 / Type12 protection, providing resistance to dust and water spray for reliable operation in industrial environments.

Q: What type of control panel comes with the FC-102P4K0T4P55H1XGXXXXSXXXXAXBXCXXXXDX?

A: This model is equipped with a Graphical Local Control Panel (LCP) for user-friendly interface and control.

Q: What type of RFI filter is integrated in the FC-102P4K0T4P55H1XGXXXXSXXXXAXBXCXXXXDX?

A: The FC-102P4K0T4P55H1XGXXXXSXXXXAXBXCXXXXDX includes an RFI filter rated as Class A1/B (C1) for electromagnetic compatibility.


Internal Product Review

  • ‘‘The FC-102P4K0T4P55H1XGXXXXSXXXXAXBXCXXXXDX is a Danfoss VLT FC 102 HVAC drive built for 380 - 480 VAC service. The graphical local control panel and IP55 / Type 12 backplate support clear commissioning and dependable enclosure protection in facility environments. RFI Class A1/B (C1) filtering makes the drive an especially clean and capable choice for HVAC installations.’’