The Danfoss FC-102P4K0T4P55H is part of the VLT FC 102 HVAC Drives series and provides a typical shaft output of 4.0 kW or 5.0 hp at 460 V. This three-phase drive features a protection level of IP55 and supports input voltages between 380 to 480 VAC with a continuous output current of up to 10 amps. Its efficiency is rated at 0.97 and it offers a maximum output frequency of 590 Hz.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-102P4K0T4P55H variable frequency drive is produced by Danfoss as part of the VLT FC 102 HVAC Drives series. This unit converts fixed-frequency mains power into adjustable-frequency output for induction motors used in air-handling units, chillers, and pump stations. Building management systems can therefore regulate motor speed to match changing flow and pressure requirements in industrial and commercial installations.

It operates from a three-phase supply of 380–480 VAC, accommodating 400 V or 460 V feeders with a permitted phase imbalance of 3.0%. Under 380–440 V service, the drive draws 9.0 A of input current and supplies a continuous motor current of 10 A. At 441–480 V, the input current decreases to 7.4 A, while the continuous motor current decreases to 8.2 A. Apparent power demand is 6.9 kVA on 400 V lines and 6.5 kVA on 460 V lines. An efficiency of 0.97 keeps conduction losses low and limits heat while the inverter delivers its rated output. The control section can produce an output frequency of up to 590 Hz, enabling operation with high-speed fan impellers. For transient overloads, the current channel sustains 110% for 60 seconds without tripping. Only two power-ups per minute are permitted to protect the DC link from inrush stress.

Heat produced during full-load conversion is 124 W, so modest control-cabinet airflow is adequate. The electronics use an IP55/Type 12 backplate, which helps shield them from dust and low-pressure water jets when the specified backplate mounting style is used with A5, B, or C frames. Pre-drilled slots on the cast-aluminum chassis simplify mounting and help position the drive securely inside the cabinet. The standard motor rating of 4.0 kW supports mid-sized air-moving equipment, including fans and pumps. The three-phase input design accommodates moderate supply variations within the permitted phase-imbalance limit. The adjustable output also allows connected motors to reduce speed during periods of lower airflow or pressure demand.

Continuous Input Current (380-440 V)
9.0 A
Continuous Input Current (441-480 V)
7.4 A
Continuous Kva (400 V)
6.9 kVA
Continuous Kva (460 V)
6.5 kVA
Continuous Output Current (380-440 V)
10 A
Continuous Output Current (441-480 V)
8.2 A
Efficiency
0.97
Estimated Power Loss
124 W
Mains Voltage
380 - 480 VAC
Maximum Output Frequency
590 Hz
Maximum Phase Imbalance
3.0%
Maximum Power-ups Per Minute
2
Mounting
Frame A5, B & C Backplate for open Drive back
Overload Rating
110% for 60 s
Power Phase
Three Phase Power
Product Group
VLT HVAC Drive
Protection Level
IP55 / Type12 Backplate
Series Identifier
102
Shaft Output At 460 V
5.0 hp
Typical Shaft Output
4.0 kW

Frequently Asked Questions about FC-102P4K0T4P55H:

Q: What input voltage range does the FC-102P4K0T4P55H drive support?

A: The FC-102P4K0T4P55H has a mains voltage rating of 380 to 480 VAC, supporting a wide range of industrial three-phase power supplies.

Q: What is the typical shaft output power of the FC-102P4K0T4P55H?

A: This model provides a typical shaft output of 4.0 kW, enabling effective operation of medium-sized HVAC equipment.

Q: What is the maximum output frequency of the Danfoss FC-102P4K0T4P55H?

A: The maximum output frequency for this drive is 590 Hz, allowing for precise speed control of connected motors.

Q: What protection rating does the FC-102P4K0T4P55H provide?

A: The protection level for this unit is IP55/Type 12, offering resistance to dust and water ingress for demanding environments.

Q: What is the continuous output current for the FC-102P4K0T4P55H drive at 380-440 V?

A: The maximum continuous output current at 380-440 V is 10 A, which supports reliable and steady operation.


Internal Product Review

  • ‘‘The FC-102P4K0T4P55H is a Danfoss VLT FC 102 HVAC drive built for three-phase power on 380 to 480 VAC systems. Efficiency rated at 0.97 and IP55/Type 12 protection support energy-conscious operation and reliable service in HVAC installations. A 110% overload rating for 60 s adds valuable tolerance for transient load demands, making this drive a strong HVAC package.’’