The Danfoss FC-102P4K0T4E20H1XGXXXXSXXXXAXBXCXXXXDX is part of the VLT FC 102 HVAC Drives series and operates on a three phase power supply with a mains voltage rating of 380 to 480 VAC. This drive features IP20 chassis protection, RFI Class A1/B filtering, and is designed for normal cabinet mounting. It also comes with a graphical local control panel for user interface.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-102P4K0T4E20H1XGXXXXSXXXXAXBXCXXXXDX is an HVAC-focused AC drive manufactured by Danfoss as part of the VLT FC 102 HVAC Drives series. This controller regulates the speed of induction motors used in air-handling units, pumps, and cooling towers within industrial automation and building management systems. By converting fixed-frequency mains power into a variable-frequency output, it maintains the required airflow or water flow while reducing energy consumption and mechanical wear. Its control functions support applications in which motor output must respond to changing heating, ventilation, and cooling demand.

The drive is designed for three-phase power and accepts a mains voltage range of 380–480 VAC, allowing direct connection to common industrial power systems. Its IP20 chassis enclosure is intended for installation inside a protected electrical cabinet. The integrated electromagnetic compatibility network is rated as RFI Class A1/B (C1) to reduce conducted interference on the incoming supply. A built-in graphical local control panel provides access to operating data, parameter menus, and drive controls through the standard language pack. The unit does not require an additional mains option, and its RFI filter is installed as part of the base configuration. The A, B, C0, C1, and D option positions do not contain additional plug-in modules, leaving the drive configured for its primary HVAC control functions.

Motor conductors enter through standard cable entries, providing conventional routing from the cabinet wiring ducts to the drive terminals. The unit uses uncoated printed circuit boards, so it is intended for dry, controlled cabinet environments without excessive moisture or airborne contaminants. Its normal cabinet mounting for A, B, and C frames allows the heat sink and chassis to align with the applicable backplate arrangement. The drive has no brake chopper, so it cannot directly control a braking resistor during regenerative operation. Kinetic energy produced during deceleration must instead be absorbed by the connected load or managed through suitable external braking equipment. Safe-stop connections use the functions available in the base drive rather than an added safety module. Adaptation B is not installed, preserving the standard mechanical and electrical arrangement for this model.

A Option
No A Option
Adaptation A
Standard Cable Entries
Adaptation B
No adaptation
B Option
No B Option
Brake - Safe Stop
No brake chopper
C Option Software
No software option
C0 Option MCO
No C0 option
C1 Option
No C1 option
Coating PCB
Not coated PCB
D Option
No D option
LCP
Graphical Loc. Cont. Panel
Mains Option
No Mains Option
Mains Voltage
380 - 480 VAC
Mounting
Normal cabinet mounting A, B, C Frames
Power Phase
Three Phase Power
Product Group
VLT HVAC Drive
Protection Level
IP20 / Chassis
RFI Filter
RFI Class A1/B (C1)
Series Identifier
102
Software Language Pack
Standard Language Pack
Software Release
Latest release std. SW.

Frequently Asked Questions about FC-102P4K0T4E20H1XGXXXXSXXXXAXBXCXXXXDX:

Q: What is the supported mains voltage range for the FC-102P4K0T4E20H1XGXXXXSXXXXAXBXCXXXXDX?

A: The FC-102P4K0T4E20H1XGXXXXSXXXXAXBXCXXXXDX supports a mains voltage range from 380 to 480 VAC for versatile international applications.

Q: What power phase does the FC-102P4K0T4E20H1XGXXXXSXXXXAXBXCXXXXDX support?

A: This drive operates using three-phase power, suitable for standard HVAC installations.

Q: What protection rating does the FC-102P4K0T4E20H1XGXXXXSXXXXAXBXCXXXXDX provide?

A: The protection level of this drive is IP20, and it features a chassis design for cabinet mounting.

Q: What type of local control panel is included on the FC-102P4K0T4E20H1XGXXXXSXXXXAXBXCXXXXDX?

A: This model comes equipped with a Graphical Local Control Panel (LCP) for on-site configuration and monitoring.

Q: What RFI filter classification is included in the FC-102P4K0T4E20H1XGXXXXSXXXXAXBXCXXXXDX?

A: The FC-102P4K0T4E20H1XGXXXXSXXXXAXBXCXXXXDX incorporates an RFI filter classified as Class A1/B (C1) for electromagnetic interference control.


Internal Product Review

  • ‘‘The FC-102P4K0T4E20H1XGXXXXSXXXXAXBXCXXXXDX is a Danfoss VLT FC 102 HVAC drive well suited for controlled and efficient building automation service. Three-phase power with a 380 to 480 VAC mains range supports stable operation in demanding HVAC applications. The graphical local control panel and IP20 chassis design make this unit a strong choice for clean cabinet integration.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo