FC-102P4K0T Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-102P4K0T is part of the VLT FC 102 HVAC Drives series and offers a rated power of 4.0 kW with a rated horsepower of 5.0 hp. This model features two analog inputs, two relay outputs, and supports three phase power. It can handle a maximum output frequency of 590 Hz, a peak starting torque of 135% for 0.5 seconds, and operates in ambient temperatures up to 50 degrees Celsius.
Internal Product Review
The FC-102P4K0T is a Danfoss VLT FC 102 HVAC drive designed for three-phase power and rated at 4.0 kW. A 10 ms torque rise time and 135% peak starting torque support precise response and confident startup performance in HVAC systems. Strong control characteristics make this drive an excellent choice for efficient, dependable operation.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-102P4K0T is a variable frequency drive manufactured by Danfoss for the VLT FC 102 HVAC Drives series. It is supplied to building automation panels where it modulates induction motor speed in air-handling units, pumps, and chillers, allowing precise airflow or water circulation without mechanical throttling. By converting fixed mains power into a controlled output waveform, the drive helps maintain temperature and pressure setpoints in commercial and industrial HVAC systems.
This model operates from three-phase power and delivers a continuous shaft rating of 4.0 kW, which corresponds to 5.0 hp for applications sized in imperial units. The inverter can raise the output frequency to 590 Hz, permitting high-speed fan service or oversynchronous pump operation when required. Its control section supports motor acceleration with a torque step that reaches the full command in 10 ms, allowing a quick response to duct-static or differential-pressure feedback. The unit tolerates an overload of 110% for 1 minute, so short process surges do not trigger trips while the power section remains within its thermal limits. Two analog inputs accept demand signals such as 0–10 V or 4–20 mA, and two relay outputs send status information to building management controllers.
The drive sustains full output at ambient temperatures up to 50 °C, eliminating the need for additional enclosure cooling in most mechanical rooms. Installation altitude can reach 1000 m without derating, which accommodates most metropolitan building sites. Motor leads may be routed through up to 150 m of shielded cable, so the unit can remain inside a central electrical room while the motor operates on a distant rooftop. During startup, peak shaft torque climbs to 135% for 0.5 seconds, aiding fan acceleration against static pressure. A maximum ramp time of 3,600 seconds enables gradual acceleration to protect belt drives. The input accommodates a mains imbalance of 3.0% while maintaining a displacement power factor of at least 0.98 and a true power factor of 0.9.