FC-102P45KT4E20H1XGXXXXSXX Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-102P45KT4E20H1XGXXXXSXX is part of the VLT FC 102 HVAC Drives series and offers a power rating of 45 kW with 60 HP output. This drive is designed for three-phase 380 to 480 VAC operation and normal cabinet mounting on A, B, or C frames. It features a graphical local control panel, IP20 chassis protection, and includes an RFI Class A1/B filter.
Internal Product Review
The FC-102P45KT4E20H1XGXXXXSXX is a Danfoss VLT FC 102 HVAC drive built for 45 kW operation on 380 - 480 VAC systems. Three-phase power handling and IP20 / chassis protection make cabinet integration straightforward in controlled industrial environments. The graphical local control panel and Class A1/B (C1) RFI filter add practical usability and clean electrical performance.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-102P45KT4E20H1XGXXXXSXX is an AC variable-frequency drive produced by Danfoss as part of the VLT FC 102 HVAC Drives series. The unit modulates induction motor speed so building automation systems can match fan or pump output to real-time thermal demand. Adjusting motor speed to the required load can reduce energy use and mechanical wear in air-handling equipment. The drive is suitable for controlling medium-sized blowers and circulation pumps in commercial or industrial HVAC systems.
This drive delivers a continuous output of 45 kW, equivalent to 60 HP, allowing it to regulate connected equipment without derating under normal operating conditions. The input section accepts 380–480 VAC from the plant mains and uses a three-phase power supply for direct connection to common industrial electrical systems. Built-in mitigation components meet the conducted-emission limits of RFI Class A1/B (C1), helping reduce electromagnetic interference near sensitive control wiring. The drive does not include a factory-installed mains disconnect or harmonic filter, so either component must be provided separately when required by the application. Its printed circuit boards are uncoated and should remain protected from excessive moisture, dust, and corrosive airborne contaminants. Adaptation B has no added adaptation, leaving the functional core in its standard configuration.
The drive has standard cable entries that align with gland plates commonly used on HVAC control panels. A graphical local control panel provides direct access to operating data and adjustable parameters without requiring a fieldbus connection. The IP20 chassis protects against accidental contact with internal components while requiring installation inside a suitable ventilated cabinet. Normal cabinet mounting is supported across the applicable A, B, and C mechanical frame sizes. Because the unit does not have a brake chopper, applications requiring regenerative stopping must use external braking equipment. The safe-stop terminal works with the upstream control and isolation equipment to stop motor torque when the safety circuit is activated.