FC-102P3K0T4Y55H3GX1OXSXXXXAXBXCXXXXDX Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
6 Minutes
6 Seconds
The Danfoss FC-102P3K0T4Y55H3GX1OXSXXXXAXBXCXXXXDX is part of the VLT FC 102 HVAC Drives series and operates with a mains voltage range of 380 to 480 VAC. This drive supports three phase power and comes equipped with standard cable entries and an RFI filter rated at Class A1/B (C1).
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-102P3K0T4Y55H3GX1OXSXXXXAXBXCXXXXDX is an AC variable frequency drive manufactured by Danfoss for the VLT FC 102 HVAC Drives series. In building automation systems, it regulates the speed of centrifugal fans, pumps, and compressors so that airflow or water flow follows real-time demand instead of requiring equipment to operate continuously at a fixed frequency. Variable-speed operation allows connected equipment to respond to changing temperature, pressure, and flow commands from a building controller. The drive can be used in air-handling units, ventilation systems, cooling towers, and chilled-water pumping installations that require controlled motor speed.
The mains input range is 380–480 VAC, allowing direct connection to common 400 V industrial and commercial distribution systems. The power stage accepts three-phase power, providing the balanced supply required for normal operation without the derating associated with a single-phase source. An integral filter rated RFI Class A1/B (C1) limits conducted high-frequency interference when motor cables remain within the permitted lengths for the installation. The drive uses standard cable entries under Adaptation A, allowing power, motor, and control wiring to pass through the existing gland plate without additional machining. This configuration has no local control panel, so operating parameters and commands must be entered through a compatible remote keypad, PC connection, or fieldbus network. Removing the local interface also prevents unintended parameter changes from the front of the installed unit.
The separate EMC configuration includes no additional C1 option, meaning that the drive does not contain a second C1 package beyond its integral radio-frequency interference filter. Installation planning should therefore account for cable routing, grounding, shielding, and any site-specific emission requirements before the motor and control wiring are connected. The product carries series code 102, which identifies its position within the FC 102 HVAC drive range. Its control functions are intended for variable-torque HVAC loads, including fans and centrifugal pumps that frequently operate below full speed. Remote communication also allows the building controller to issue speed references, monitor operating status, and coordinate the drive with other heating, ventilation, and air-conditioning equipment.
Frequently Asked Questions about FC-102P3K0T4Y55H3GX1OXSXXXXAXBXCXXXXDX:
Q: What mains voltage range is supported by the Danfoss FC-102P3K0T4Y55H3GX1OXSXXXXAXBXCXXXXDX?
A: This drive operates with a mains voltage range from 380 to 480 VAC.
Q: Is the Danfoss FC-102P3K0T4Y55H3GX1OXSXXXXAXBXCXXXXDX compatible with three phase power?
A: The FC-102P3K0T4Y55H3GX1OXSXXXXAXBXCXXXXDX is designed for three phase power systems.
Q: What type of RFI filter is included with the FC-102P3K0T4Y55H3GX1OXSXXXXAXBXCXXXXDX?
A: This model comes equipped with an RFI filter classified as Class A1/B (C1).
Q: Does the FC-102P3K0T4Y55H3GX1OXSXXXXAXBXCXXXXDX have a local control panel?
A: This drive does not include a Local Control Panel (LCP).
Q: What kind of cable entry option is available on the FC-102P3K0T4Y55H3GX1OXSXXXXAXBXCXXXXDX?
A: Standard cable entries are provided on this model for power and control connections.