FC-102P30KT4P55H1XGX1XXSXXXXAXBXCXXXXDX Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss FC-102P30KT4P55H1XGX1XXSXXXXAXBXCXXXXDX is part of the VLT FC 102 HVAC Drives series. It features a power rating of 30 kW, supports three phase power at 380 to 480 VAC, and provides 40 horsepower. This drive includes a graphical local control panel, mains disconnect, frame A5 B & C backplate, and offers IP55/Type12 backplate protection.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-102P30KT4P55H1XGX1XXSXXXXAXBXCXXXXDX is an AC variable frequency drive produced by Danfoss for the VLT FC 102 HVAC Drives series. The unit converts fixed-frequency mains power into a controllable output, allowing building automation systems to regulate centrifugal fans, pumps, and compressors according to real-time load. This variable-speed operation can reduce unnecessary energy use when connected equipment does not require full output. The drive is supplied on a Frame A5, B, or C backplate that leaves the rear open, simplifying panel ventilation when the unit is mounted inside a mechanical-room enclosure.
Its mechanical output ceiling is 40 HP, equivalent to 30 kW of electrical drive capability and suitable for medium-sized air-handling equipment. The input section accepts 380 to 480 VAC from a three-phase power supply, so phase conversion is not required when connecting the drive to compatible industrial mains. A factory-installed mains disconnect isolates incoming power during maintenance. The drive does not include a brake chopper, so external dynamic braking components are required when an application needs rapid deceleration. Cables enter through the standard cable entries designated as Adaptation A, providing an organized route for power and control wiring within the enclosure.
The enclosure uses an IP55 / Type 12 backplate, allowing the drive to resist dust and directed water jets when the open-back assembly is properly sealed to the cabinet wall. Conducted emissions are limited by the integrated RFI Class A1/B (C1) filter, which helps HVAC systems meet common building electromagnetic compatibility requirements. Parameters are entered through the graphical local control panel, which presents operating data and menu selections in a readable format. The standard language pack provides multiple interface languages for configuring commands, monitoring drive status, and reviewing diagnostic information. The control software is supplied as the latest standard software release, and no separate software option is activated. The printed circuit boards are not coated, so the installation location should remain free of corrosive vapors that could damage exposed electronic components over time.