FC-102P30KT4E55H2XGXXXXSX Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The FC-102P30KT4E55H2XGXXXXSX is a 40 HP HVAC drive with a power rating of 30 kW and operates on three phase power at 380 to 480 VAC. Manufactured by Danfoss as part of the VLT FC 102 HVAC Drives series, this unit features IP55/Type 12 protection, standard cable entries, and a graphical local control panel. It also includes an RFI filter and does not have a brake chopper or coated PCB.
Internal Product Review
The FC-102P30KT4E55H2XGXXXXSX is a Danfoss VLT HVAC drive with a 30 kW power rating. Operation across 380 to 480 VAC and the graphical local control panel support efficient setup and solid system integration. IP55 / Type 12 protection is a strong advantage for HVAC installations requiring dependable enclosure performance.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-102P30KT4E55H2XGXXXXSX is an AC variable-frequency drive manufactured by Danfoss for the VLT FC 102 HVAC Drives series. It belongs to the VLT HVAC Drive product group and carries the internal identifier 102. By converting steady mains power into a regulated output waveform, it allows building automation controllers to adjust the speed of motors on fans, pumps, and compressors. Variable-speed operation can reduce the energy that ventilation and chilled-water systems would otherwise lose through throttling devices.
The drive has a rated output of 30 kW (40 HP), making it suitable for medium-sized air handlers or process pumps. It accepts supply voltages from 380–480 VAC on three-phase power networks, so a step-up transformer is not required when the unit is connected to typical industrial mains. The IP55 / Type 12 enclosure protects the electronics against dust and water jets, allowing installation in plant rooms without a separate cabinet. Because the configuration has no mains option, line-side disconnects and overcurrent protection must be installed externally. The printed circuit boards are not coated, so the drive should be used in locations that maintain normal HVAC cleanliness levels and limit exposure to airborne contaminants. Adaptation B is set to no adaptation, leaving the drive in its standard configuration for the listed application.
Conducted-emission control is provided by an integrated RFI filter, helping the system comply with electromagnetic compatibility limits on shared power buses. Field wiring passes through standard cable entries, which simplify gland plate preparation and conductor routing during installation. A front-mounted graphical local control panel provides parameter editing, trend viewing, status monitoring, and local jog commands without external tools. The absence of a brake chopper means regenerative energy cannot be dissipated through an onboard resistor bank. Applications with overhauling loads or rapid deceleration requirements may therefore require external provisions for controlling excess regenerative energy. The drive is intended primarily for airflow and hydronic speed control where enclosure sealing and conducted-emission filtering are required.