FC-102P2K2T4Z55H1XGXXXXSXXXXA0BXCXXXXDX Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
3 Minutes
36 Seconds
The FC-102P2K2T4Z55H1XGXXXXSXXXXA0BXCXXXXDX is an HVAC drive from Danfoss's VLT FC 102 HVAC Drives series. It supports three phase power with a voltage range of 380 to 480 VAC and includes a graphical local control panel. The drive features a PROFIBUS DP MCA 101 communication option and is equipped with an RFI Class A1/B filter.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-102P2K2T4Z55H1XGXXXXSXXXXA0BXCXXXXDX is a variable frequency drive manufactured by Danfoss for the VLT FC 102 HVAC Drives series. In ventilation and chilled-water loops, it modulates induction motor speed to maintain pressure, temperature, or airflow setpoints while reducing energy drawn from the mains. The drive varies its output frequency and voltage according to the control demand, allowing connected fans and pumps to operate at the speed required by the system. Local control adjustments, operating data, and diagnostic messages are available through a graphical LCP, which provides direct access to drive parameters from the front panel.
The unit connects to building management systems through a built-in PROFIBUS DP MCA 101 fieldbus card, allowing commands and operating data to pass between the drive and a central controller. Panel wiring is routed through standard cable entries, providing conventional access for power, motor, control, and communication conductors. The drive operates from a 380–480 VAC supply, and its three-phase power input supports common commercial and industrial distribution systems. An integrated RFI Class A1/B (C1) filter limits conducted electrical interference that could otherwise return to the connected power network. The unit has no brake chopper, so an external method of handling regenerative energy may be necessary when high-inertia loads must decelerate rapidly.
The drive uses an uncoated printed circuit board, which supports heat dissipation but requires installation in a clean, dry electrical enclosure with suitable protection from moisture and airborne contamination. The Adaptation B position has no adaptation module installed, and the B, C0, C1, and D option positions are also unpopulated. Its application configuration does not include an additional software option. The control interface uses the standard language pack and the latest standard software release available for this configuration. A mains disconnect is not fitted, so an appropriate upstream disconnecting device must provide electrical isolation for service and emergency shutdown requirements.
Frequently Asked Questions about FC-102P2K2T4Z55H1XGXXXXSXXXXA0BXCXXXXDX:
Q: What communication interface is included with the Danfoss FC-102P2K2T4Z55H1XGXXXXSXXXXA0BXCXXXXDX drive?
A: The FC-102P2K2T4Z55H1XGXXXXSXXXXA0BXCXXXXDX is equipped with the PROFIBUS DP MCA 101 communication option.
Q: What input voltage range does the Danfoss FC-102P2K2T4Z55H1XGXXXXSXXXXA0BXCXXXXDX drive support?
A: This drive supports a mains voltage range of 380 to 480 VAC.
Q: What type of RFI filter is included in the FC-102P2K2T4Z55H1XGXXXXSXXXXA0BXCXXXXDX drive?
A: The Danfoss VLT FC 102 model features RFI Class A1/B (C1) filtering for electromagnetic compatibility.
Q: What type of control panel is provided with the Danfoss FC-102P2K2T4Z55H1XGXXXXSXXXXA0BXCXXXXDX?
A: This drive includes a graphical local control panel (LCP) for user interaction and setup.
Q: What power phase does the Danfoss FC-102P2K2T4Z55H1XGXXXXSXXXXA0BXCXXXXDX drive use?
A: The FC-102P2K2T4Z55H1XGXXXXSXXXXA0BXCXXXXDX operates using three phase power.