The FC-102P1K5T4E20H1XXXXXXSXXXXAXBXCXXXXDX is an HVAC drive from Danfoss, part of the VLT FC 102 HVAC Drives series. It is designed for three phase power with a mains voltage range of 380 to 480 VAC and mounts in normal cabinet mounting frames. The drive has IP20 chassis protection and comes with an RFI Class A1/B filter.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-102P1K5T4E20H1XXXXXXSXXXXAXBXCXXXXDX is a variable frequency drive manufactured by Danfoss for the VLT FC 102 HVAC Drives series. In building automation, it regulates the speed of centrifugal pumps, fans, and compressors so energy use can follow real-time demand instead of forcing motors to run continuously at line frequency. By converting fixed mains power into a programmable output, the unit helps control systems maintain airflow, pressure, and temperature with tighter accuracy and reduced mechanical wear. This operating method can also reduce abrupt starts and support smoother part-load operation in HVAC equipment.

This model accepts a nominal input of 380 – 480 VAC delivered as three-phase power, so it connects directly to common industrial feeders without transformers. The chassis protection rating is IP20 / Chassis, which provides finger-safe terminals but still requires installation inside an enclosure where dust or moisture may be present. An integrated electromagnetic filter meets RFI Class A1/B (C1) limits, helping facilities comply with conducted-emission requirements on public low-voltage networks. Wiring enters through standard cable entries, which simplifies gland plate selection and avoids custom knockouts. Because the electrical interface follows common HVAC panel practice, the drive can be integrated into building control cabinets without unusual supply or cable-routing provisions.

There is no local control panel, so parameter access relies on remote fieldbus connections or PC-based tools. This arrangement suits centrally supervised installations where operating data and settings are managed from a building controller rather than from the drive face. The control boards use an uncoated PCB, so the cabinet should protect the electronics from corrosive atmospheres. Mounting follows normal cabinet mounting for A, B, and C frames, which aligns the heat sink with standard rail spacing and airflow paths. The drive includes the latest standard software release, which provides updated motor-control algorithms and HVAC functions such as flow optimization and automatic energy reporting.

A Option
No A Option
Adaptation A
Standard Cable Entries
Adaptation B
No adaptation
B Option
No B Option
Brake - Safe Stop
No brake chopper
C Option Software
No software option
C0 Option MCO
No C0 option
C1 Option
No C1 option
Coating PCB
Not coated PCB
D Option
No D option
LCP
No Loc. Cont. Panel
Mains Option
No Mains Option
Mains Voltage
380 - 480 VAC
Mounting
Normal cabinet mounting A, B, C Frames
Power Phase
Three Phase Power
Product Group
VLT HVAC Drive
Protection Level
IP20 / Chassis
RFI Filter
RFI Class A1/B (C1)
Series Identifier
102
Software Language Pack
Standard Language Pack
Software Release
Latest release std. SW.

Frequently Asked Questions about FC-102P1K5T4E20H1XXXXXXSXXXXAXBXCXXXXDX:

Q: What is the mains voltage range for the Danfoss FC-102P1K5T4E20H1XXXXXXSXXXXAXBXCXXXXDX drive?

A: The FC-102P1K5T4E20H1XXXXXXSXXXXAXBXCXXXXDX operates with a mains voltage of 380 to 480 VAC.

Q: What type of power phase does the FC-102P1K5T4E20H1XXXXXXSXXXXAXBXCXXXXDX require?

A: This model is designed for three-phase power input, suitable for industrial electrical systems.

Q: What is the protection rating of the FC-102P1K5T4E20H1XXXXXXSXXXXAXBXCXXXXDX?

A: The drive offers a protection level of IP20 and comes in a chassis format, suitable for standard cabinet installations.

Q: What RFI filter class is used in the FC-102P1K5T4E20H1XXXXXXSXXXXAXBXCXXXXDX?

A: It is equipped with an RFI filter rated for Class A1/B (C1), helping to reduce electrical interference.

Q: Does the FC-102P1K5T4E20H1XXXXXXSXXXXAXBXCXXXXDX feature an integrated brake chopper?

A: This drive does not have a brake chopper, so it cannot perform safe stop braking operations internally.


Internal Product Review

  • ‘‘The FC-102P1K5T4E20H1XXXXXXSXXXXAXBXCXXXXDX is a Danfoss VLT HVAC drive built for 380-480 VAC mains. Three-phase power architecture and an RFI Class A1/B (C1) filter support clean, stable integration in HVAC control cabinets. IP20 / chassis protection and normal cabinet mounting make this unit a strong choice for streamlined panel installations.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo