FC-102P1K5T4E20H1XXXXXXSXXX Danfoss

Ask for Availability

Current response time:
6 Minutes 35 Seconds

Preparing your secure checkout page...

The Danfoss FC-102P1K5T4E20H1XXXXXXSXXX is a VLT FC 102 HVAC Drive designed for normal cabinet mounting and operates on three-phase power with a mains voltage range of 380 to 480 VAC. This product features an IP20 chassis protection level, standard cable entries, and an RFI Class A1/B filter.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-102P1K5T4E20H1XXXXXXSXXX is an AC variable frequency drive manufactured by Danfoss for the VLT FC 102 HVAC Drives series. Within air-handling units and chilled-water pump systems, the unit adjusts motor speed so that airflow or water flow follows real-time building demands. This variable-speed operation can improve energy efficiency and reduce mechanical wear in industrial and commercial automation systems. The drive provides a dedicated control platform for heating, ventilation, and air-conditioning equipment that requires responsive motor regulation under changing loads.

The power section accepts a line supply of 380 to 480 VAC delivered as three-phase power, matching common distribution voltages in mechanical-room panels. Its IP20 chassis protects against accidental finger contact while allowing cooling air to circulate when the drive is installed inside a suitable cabinet. The open chassis design requires an enclosure that provides appropriate protection from moisture, conductive debris, and direct contact with internal components. Conducted emissions are limited by the integrated RFI Class A1/B (C1) filter, allowing connection to compatible building power networks without a separate line filter. Field conductors enter through standard cable entries, simplifying gland-plate preparation while supporting the cable spacing needed for electromagnetic compatibility. The cabinet must provide adequate ventilation and clearance around the drive so that heat can leave the power electronics during continuous operation.

The drive has no brake chopper, so regenerative energy must be managed by the connected motor system or suitable external equipment when the application produces significant overhauling loads. The factory configuration includes no local control panel, making operator interaction dependent on a separately selected interface or remote control system. It also includes no optional line-supply hardware, so any additional input disconnects, fuses, or conditioning components must be provided elsewhere in the installation. The control boards use an uncoated printed circuit board design, which requires the cabinet environment to remain within the permitted humidity and contamination limits. No supplementary terminal blocks or conduit plates are preinstalled, allowing the standard cabinet cable arrangement to be used. These installation conditions are particularly important in mechanical rooms where condensation, dust, or airborne contaminants could otherwise reach exposed electronic assemblies.

Adaptation A
Standard Cable Entries
Adaptation B
No adaptation
Brake - Safe Stop
No brake chopper
Coating PCB
Not coated PCB
LCP
No Loc. Cont. Panel
Mains option
No Mains Option
Mains Voltage
380 - 480 VAC
Mounting
Normal cabinet mounting A, B, C Frames
Power Phase
Three Phase Power
Product Group
VLT HVAC Drive
Protection Level
IP20 / Chassis
RFI filter
RFI Class A1/B (C1)
Series Identifier
102
Software Release
Latest release std. SW.

Frequently Asked Questions about FC-102P1K5T4E20H1XXXXXXSXXX:

Q: What input voltage does the FC-102P1K5T4E20H1XXXXXXSXXX drive accept?

A: The Danfoss FC-102P1K5T4E20H1XXXXXXSXXX supports a mains voltage range of 380 to 480 VAC.

Q: What power phase is required for operating the FC-102P1K5T4E20H1XXXXXXSXXX?

A: This drive is designed for three-phase power input.

Q: What is the protection level of the FC-102P1K5T4E20H1XXXXXXSXXX drive?

A: The FC-102P1K5T4E20H1XXXXXXSXXX is rated with an IP20 protection level and is supplied as a chassis unit.

Q: What type of RFI filter does the FC-102P1K5T4E20H1XXXXXXSXXX use?

A: This Danfoss drive comes equipped with an RFI filter rated as Class A1/B (C1).

Q: How is the FC-102P1K5T4E20H1XXXXXXSXXX generally mounted?

A: The drive is intended for normal cabinet mounting with A, B, or C frame options.


Internal Product Review

  • ‘‘The FC-102P1K5T4E20H1XXXXXXSXXX is a Danfoss VLT HVAC drive designed for three-phase power systems. Operation across 380 to 480 VAC and IP20 chassis protection supports dependable cabinet integration in controlled industrial environments. Normal cabinet mounting and an RFI Class A1/B (C1) filter make the unit a strong choice for clean, practical HVAC drive installations.’’