4.94 based on 222 reviews

🙶 a+ fast delivery 🙷

FC-102P1K1 Danfoss

In-Stock, Ships 1-2 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The FC-102P1K1 is a well-executed Danfoss VLT HVAC drive with a 1.1 kW power rating and 3 A nominal output current. A 0.5% FS analog input max error and 5 ms digital input scan interval support precise, responsive control in HVAC duty. A strong choice for dependable low-power drive performance.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-102P1K1 is an AC variable frequency drive produced by Danfoss as part of the VLT FC 102 HVAC Drives series. In building automation, the unit adjusts induction motor speed so that fans, pumps, and compressors can match real-time demand rather than operate at a constant frequency. By converting fixed-frequency mains power into a modulated three-phase output, the drive helps reduce energy consumption and mechanical wear in air-handling and chilled-water systems. Its variable-speed operation also allows connected equipment to respond smoothly to changing flow, pressure, or temperature requirements.

The inverter is rated for a continuous shaft power of 1.1 kW, corresponding to a nominal motor current of 3 A at the output terminals. The drive has two analog inputs that accept 0–10 V or 0/4–20 mA signals, allowing simultaneous flow and temperature feedback. Six programmable logic channels accommodate start, stop, and operating mode commands, while their 28 V DC limit supports direct connection to typical building-management controllers. The six digital inputs operate with a five-millisecond scan interval to keep control latency low. One analog output, two pulse counters, and two form-C relays provide operating status and process information to external monitoring equipment.

The drive’s analog conversion error does not exceed 0.5% FS, supporting accurate proportional and PID control loops. Two transistor stages provide two digital outputs for run indication or fault signaling. The integrated mains converter can deliver 1.5 HP to compatible NEMA-frame motors. The unit tolerates supply voltage deviations of ±10% and frequency deviations of plus or minus five percent without derating. Its short-circuit current rating reaches 100 kA at 480/600 V, which supports coordination with properly selected upstream protective devices. The available analog, digital, pulse, and relay connections allow the drive to exchange commands and status data with common HVAC control systems.

Analog Input Max Error
0.5% FS
Analog Inputs
2
Analog Outputs
1
Digital Input Max Voltage
28 V DC
Digital Input Scan Interval
5 ms
Digital Inputs
6
Digital Outputs
2
Horse Power
1.5 HP
Mains Frequency Tolerance
±5%
Mains Voltage Tolerance
±10%
Nominal Output Current
3 A
Power Rating
1.1 kW
Product Group
VLT HVAC Drive
Pulse Inputs
2
Relay Outputs
2
Sccr (480/600 V)
100 kA
Series Identifier
102

Frequently Asked Questions about FC-102P1K1:

Q: What is the power rating of the FC-102P1K1 drive?

A: The FC-102P1K1 HVAC drive has a power rating of 1.1 kW, making it suitable for small to medium-sized applications.

Q: How many digital inputs are available on the FC-102P1K1?

A: This model supports up to six digital inputs, allowing for flexible integration with external controls and switches.

Q: What is the nominal output current of the FC-102P1K1?

A: The nominal output current of this drive is 3 A, ensuring consistent performance for compatible HVAC motors.

Q: How many analog inputs does the FC-102P1K1 have, and what is the maximum error?

A: The FC-102P1K1 provides two analog inputs with a maximum error of 0.5% full scale, ensuring accurate signal processing.

Q: What is the mains voltage tolerance for the FC-102P1K1 HVAC drive?

A: For input voltage changes, this drive can handle up to ±10% mains voltage tolerance, offering operational stability.

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo