FC-102P18KT4E55H1XGXXXXSXXXXAXBXCXXXXDX Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
3 Minutes
42 Seconds
The Danfoss FC-102P18KT4E55H1XGXXXXSXXXXAXBXCXXXXDX is a drive from the VLT FC 102 HVAC Drives series with a power rating of 18.5 kW and 25 HP. It is designed for three phase power operation at 380 to 480 VAC and features an IP55 / Type 12 protection level. This model includes a graphical local control panel and an RFI filter rated at Class A1/B (C1).
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-102P18KT4E55H1XGXXXXSXXXXAXBXCXXXXDX variable frequency drive is produced by Danfoss within the VLT FC 102 HVAC Drives series. It converts fixed-frequency plant power into a regulated output for centrifugal fans, pumps, and compressors used in building automation. By delivering adjustable torque and speed, the unit allows ventilation or chiller equipment to match real-time demand, improving energy efficiency and reducing mechanical stress on connected HVAC machinery. Its regulated output also supports smooth acceleration and deceleration, which can reduce abrupt pressure changes in air and water systems.
Its output capability is rated at 18.5 kW, which corresponds to 25 HP under continuous load. The input stage accommodates 380 to 480 VAC utility supplies and is designed for three-phase power, so no phase conversion is required in typical switchboards. An enclosure classified as IP55 / Type 12 shields the internal electronics against dust and low-pressure water jets, permitting installation in mechanical rooms without a separate cabinet. The drive does not include a brake chopper, so dynamic braking energy must be handled externally when rapid deceleration is needed. The printed circuit board is not coated, which limits use to dry indoor areas where airborne contaminants are minimal. Installation areas should therefore remain free from condensation, conductive dust, and corrosive vapors that could affect exposed electronic components.
Control and parameter adjustments are performed through a graphical local control panel, which presents operating values and menus using the standard language pack supplied with the drive. Cabling enters the housing through standard cable entries, allowing power and control conductors to be routed through the designated gland plate. The integrated radio-frequency interference network meets RFI Class A1/B (C1) emission limits for public low-voltage power systems. The graphical panel supports local overrides and service diagnostics, allowing operating status, alarms, and parameter values to be viewed directly at the unit. The numeric series identifier is 102, aligning the drive with the associated VLT HVAC Drive product group. Its base configuration does not include auxiliary filters, fieldbus cards, or integrated safety relays, so any required external functions must be provided separately.
Frequently Asked Questions about FC-102P18KT4E55H1XGXXXXSXXXXAXBXCXXXXDX:
Q: What is the power rating of the FC-102P18KT4E55H1XGXXXXSXXXXAXBXCXXXXDX drive?
A: This drive has a power rating of 18.5 kW, making it suitable for medium to large HVAC applications.
Q: What mains voltage and phase does this VLT FC 102 drive support?
A: The drive operates on three-phase power with a voltage range of 380 to 480 VAC.
Q: Which type of control panel is included with this drive?
A: The FC-102P18KT4E55H1XGXXXXSXXXXAXBXCXXXXDX comes with a graphical local control panel for easy operation and monitoring.
Q: What is the protection level of the FC-102P18KT4E55H1XGXXXXSXXXXAXBXCXXXXDX?
A: This model features an IP55 / Type 12 enclosure, which offers protection against dust and water jets.
Q: What type of RFI filter does this Danfoss drive include?
A: A class A1/B (C1) RFI filter is integrated to reduce electromagnetic interference in this drive.