FC-102P18KT4E20H3XG

Ask for Availability

Preparing your secure checkout page...

The FC-102P18KT4E20H3XG controller module features two CAN interfaces, an input voltage range of 100-240 volts AC, and a power consumption of 14.5 watts, with network capability. Part of the VLT FC 102 HVAC Drives series manufactured by Danfoss, it requires a separately ordered TB712 terminal block and is mounted using a screw-in module system.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-102P18KT4E20H3XG VLT HVAC Drive by Danfoss serves to deliver accurate power management of three-phase HVAC systems with optimal operational effectiveness. The system provides powerful capabilities that improve performance levels, especially during operations where stable thermal conditions must be maintained.

At 18.5 KW the FC-102P18KT4E20H3XG VLT HVAC drive effectively addresses demanding electrical loads. The drive enables extended operation at the 37.5 A current capacity. This ensures continuous power delivery through optimal temperature regulation. The drive manages intermittent currents up to 41.2 A which accommodates short bursts of increased power demand. The drive functions using a mains voltage range from 380 to 480 VAC to meet different power supply standards of operation. The FC-102P18KT4E20H3XG VLT HVAC drive operates to peak performance between temperatures of -10 to +50 °C. This assures a dependable functionality when operating in various climatic environments. The storage temperature range of -25 °С to +65 °С enables this component to handle non-operational conditions effectively. This device holds an IP20 rating which defends against significant physical objects. However, it lacks sufficient defense against wet conditions suitable for its planned room-based deployment. The drive's EMC filter prevents electronic interference which protects nearby devices as well as the drive integrity.

Communication and integration into FC-102P18KT4E20H3XG VLT HVAC drive are facilitated via an RS485 interface. This supports Modbus RTU and FC protocols which ensures versatile connectivity options for system management. This design prioritizes controlled spaces that do not require brake chopper devices or coated PCBs since it omits such protective functions. The drive's graphical control interface improves setup control together with system monitoring through an easy-to-use interface. Each feature contributes to a dependable solution that optimizes performance for easy operation. This satisfies the demanding climate maintenance requirements of commercial and residential buildings.

Can Interfaces
2
Coating PCB
Not coated PCB
Enclosure
IP-20
Input Voltage Range
100-240 VAC
Interfaces
2 CAN interfaces
Isolation
Electrically isolated
Mains Voltage
380 - 480 VAC
Mounting
Screw-in module, order TB712 terminal block separately
Network Capability
Yes
Phase
Three phase
Power 110% (NO)
18.5 kW
Power Consumption
14.5 W
Power Rating
18.5 KW
Power Supply
100-240 VAC
Type
Controller Module

Frequently Asked Questions about FC-102P18KT4E20H3XG:

Q: How does the EMC filter benefit the Danfoss FC-102P18KT4E20H3XG VLT HVAC Drive?

A: The EMC filter in the Danfoss FC-102P18KT4E20H3XG VLT HVAC Drive minimizes electromagnetic interference, ensuring stable system operation. This protects nearby sensitive equipment from electrical noise.

Q: Why does the Danfoss FC-102P18KT4E20H3XG VLT HVAC Drive lack a brake chopper?

A: The Danfoss FC-102P18KT4E20H3XG VLT HVAC Drive is designed for HVAC applications where regenerative braking is not a priority. This omission reduces unnecessary complexity for controlled environments.

Q: Why does the FC-102P18KT4E20H3XG VLT HVAC Drive have an IP20 rating?

A: The Danfoss FC-102P18KT4E20H3XG VLT HVAC Drive is designed for indoor environments where moisture protection is unnecessary. The IP20 rating safeguards against solid objects but not liquids.

Q: How does the RS485 Modbus RTU support system integration in FC-102P18KT4E20H3XG VLT HVAC Drive?

A: The RS485 Modbus RTU in the Danfoss FC-102P18KT4E20H3XG VLT HVAC Drive enables seamless communication with HVAC automation systems. It ensures efficient data exchange for precise power and thermal control.

Q: How does the FC protocol enhance performance in FC-102P18KT4E20H3XG VLT HVAC Drive?

A: The FC protocol in the Danfoss FC-102P18KT4E20H3XG VLT HVAC Drive ensures optimized communication with compatible HVAC control systems. This improves real-time response and system efficiency.


Internal Product Review

  • ‘‘The Danfoss FC-102P18KT4E20H3XG VLT HVAC Drive is a robust choice for HVAC applications. The drive has 18.5 KW power, reliable RS485 communication, and 41.2 A peak current handling. Its EMC filter minimizes interference, while the IP20-rated design ensures durability.’’