4.95 based on 202 reviews

🙶 I have always received exceptional service and support in my many years of working with Wake Industrial. 🙷

FC-102P15KT4E66H3XGX1XXSXXXXAXBXCXXXDX Danfoss

Ask for Availability

Current response time:
6 Minutes 0 Seconds

Preparing your secure checkout page...

The Danfoss FC-102P15KT4E66H3XGX1XXSXXXXAXBXCXXXDX belongs to the VLT FC 102 HVAC Drives series and features a power rating of 15 kW with 20 HP output. It supports three phase power at 380 to 480 VAC and is equipped with a graphical local control panel. This model offers IP66 / NEMA 4X protection and comes with an RFI Class A1/B (C1) filter.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-102P15KT4E66H3XGX1XXSXXXXAXBXCXXXDX is an AC variable frequency drive manufactured by Danfoss for the VLT FC 102 HVAC Drives series. The unit is designed for building automation and light industrial systems that require variable-speed control of centrifugal fans, pumps, and compressors. It converts a fixed utility supply into a modulated output that adjusts motor speed according to load demand. Precise speed regulation can reduce unnecessary energy consumption while helping ventilation, pressure, and flow systems maintain stable operating conditions. Onboard control interfaces also allow the drive to exchange commands and operating data with supervisory control systems.

The electrical section accepts 380–480 VAC from a three-phase power network, making the drive suitable for common industrial power systems. Its continuous output is rated at 15 kW, which corresponds to 20 HP for medium-sized air-handling equipment, circulation pumps, and booster stations. The polyester enclosure carries an IP66 / NEMA 4X rating, protecting internal components against dust and washdown water. This enclosure allows wall mounting in suitable locations without requiring a separate protective cabinet. The configuration does not include a brake chopper, so deceleration energy must be managed through the motor or compatible external equipment. Its printed circuit boards are not conformally coated, which should be considered when selecting an installation location with airborne moisture or corrosive contaminants.

The built-in mains disconnect isolates the connected power circuit and provides a local means of disconnecting the drive from its incoming supply. Local operation, parameter adjustment, and diagnostic viewing are handled through the graphical local control panel, which presents operating values and drive settings through a visual interface. Conducted electrical emissions are reduced by an integrated RFI Class A1/B (C1) filter, supporting installations that require C1 filtering without an additional plug-in board. The numeric designator 102 indicates the platform’s HVAC-oriented control functions and sensor scaling. Standard cable entries provide defined routing points for incoming power, motor conductors, and control wiring. The absence of a brake chopper also means that stopping profiles must remain compatible with the connected motor, load inertia, and any external energy-management equipment.

A Option
No A Option
Adaptation A
Standard Cable Entries
Adaptation B
No adaptation
B Option
No B Option
Brake - Safe Stop
No brake chopper
C0 Option MCO
No C0 option
C1 Option
No C1 option
Coating PCB
Not coated PCB
Horse Power
20 HP
LCP
Graphical Loc. Cont. Panel
Mains Option
Mains Disconnect
Mains Voltage
380 - 480 VAC
Power Phase
Three Phase Power
Power Rating
15 KW
Product Group
VLT HVAC Drive
Protection Level
IP66 / NEMA 4X
RFI Filter
RFI Class A1/B (C1)
Series Identifier
102
Software Language Pack
Standard Language Pack
Software Release
Latest release std. SW.

Frequently Asked Questions about FC-102P15KT4E66H3XGX1XXSXXXXAXBXCXXXDX:

Q: What is the maximum horsepower rating for the FC-102P15KT4E66H3XGX1XXSXXXXAXBXCXXXDX drive?

A: This drive supports a 20 horsepower capacity, providing reliable performance for large HVAC systems.

Q: What type of power phase does the FC-102P15KT4E66H3XGX1XXSXXXXAXBXCXXXDX require?

A: The FC-102P15KT4E66H3XGX1XXSXXXXAXBXCXXXDX operates on a three-phase power supply.

Q: What is the mains voltage range for the FC-102P15KT4E66H3XGX1XXSXXXXAXBXCXXXDX?

A: The drive is rated for input voltages between 380 and 480 VAC, allowing use with a variety of industrial power sources.

Q: What is the protection level of the FC-102P15KT4E66H3XGX1XXSXXXXAXBXCXXXDX?

A: This model features IP66 / NEMA 4X protection, meaning it is suitable for harsh environments requiring resistance to dust and water ingress.

Q: What type of control panel is included with the FC-102P15KT4E66H3XGX1XXSXXXXAXBXCXXXDX?

A: A graphical local control panel is included with this drive, providing an intuitive interface for configuration and monitoring.


Internal Product Review

  • ‘‘The FC-102P15KT4E66H3XGX1XXSXXXXAXBXCXXXDX is a Danfoss VLT HVAC drive for 380 - 480 VAC applications. Three-phase power input and IP66 / NEMA 4X protection make the unit especially well suited for demanding HVAC installations. A graphical local control panel with a mains disconnect rounds out a highly serviceable and capable drive package.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo