4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

FC-102P11KT4P55H1XGX1XXSXXXXAXBXCXXXXDX Danfoss

In-Stock, Ships 3-5 Days

Current response time:
5 Minutes 21 Seconds

Preparing your secure checkout page...

The Danfoss FC-102P11KT4P55H1XGX1XXSXXXXAXBXCXXXXDX is part of the VLT FC 102 HVAC Drives series and offers a power rating of 11 kW with support for three-phase 380 - 480 VAC mains voltage. This drive provides 15 horsepower and is equipped with a graphical local control panel and an IP55 / Type12 protection level backplate. It also features a RFI Class A1/B filter and a mains disconnect option for added functionality.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-102P11KT4P55H1XGX1XXSXXXXAXBXCXXXXDX is a variable-frequency drive produced by Danfoss for the VLT FC 102 HVAC Drives series. It provides closed-loop speed control for centrifugal fans, pumps, and compressors used in air-handling systems and chiller circuits. Building-management systems can use the drive to regulate motor speed and torque in response to changing temperature and pressure setpoints. This control method reduces unnecessary motor operation when the connected equipment does not require full output. The drive is intended for commercial HVAC systems that require adjustable flow, pressure, or cooling capacity throughout the operating cycle.

The drive delivers a continuous output of 11 kW, which corresponds to 15 HP for midsize blower and pump loads. Its inverter accepts a supply range of 380–480 VAC from a three-phase power network. A built-in supply disconnect allows the incoming electrical source to be isolated during maintenance without requiring a separate disconnect at the drive. The enclosure is rated IP55 / Type 12, protecting internal components from dust, water jets, and common indoor contaminants. It supports installation with the applicable Frame A5, B, or C backplate mounting kit and does not require a separate protective cabinet under suitable installation conditions. The drive does not include a brake chopper, and its printed circuit board does not have a conformal coating. These characteristics should be considered when selecting the installation location and arranging protection from moisture, chemicals, and excessive airborne contamination.

Local operation is provided through a graphical local control panel, which presents operating values, alarms, and adjustable parameters in a readable menu format. Remote wiring passes through standard cable entries associated with Adaptation A, allowing power and control conductors to be routed into the enclosure. Conducted and radiated emissions are limited by an integrated Class A1/B (C1) RFI filter, supporting use in first-environment installations when the applicable installation practices are followed. The Standard Language Pack supplies multilingual prompts for local operation and parameter entry. Series Identifier 102 indicates the drive platform, while the default HVAC parameter profile supports common fan, pump, and compressor control functions. Accessory positions A, B, C0, C1, and D are unassigned, so the unit does not include additional I/O, motion-control, or application-option modules in this configuration.

A Option
No A Option
Adaptation A
Standard Cable Entries
Adaptation B
No adaptation
B Option
No B Option
Brake - Safe Stop
No brake chopper
C Option Software
No software option
C0 Option MCO
No C0 option
C1 Option
No C1 option
Coating PCB
Not coated PCB
D Option
No D option
Horse Power
15 HP
LCP
Graphical Loc. Cont. Panel
Mains Option
Mains Disconnect
Mains Voltage
380 - 480 VAC
Mounting
Frame A5, B & C Backplate for open Drive back
Power Phase
Three Phase Power
Power Rating
11 KW
Product Group
VLT HVAC Drive
Protection Level
IP55 / Type12 Backplate
RFI Filter
RFI Class A1/B (C1)
Series Identifier
102
Software Language Pack
Standard Language Pack
Software Release
Latest release std. SW.

Frequently Asked Questions about FC-102P11KT4P55H1XGX1XXSXXXXAXBXCXXXXDX:

Q: What input mains voltage range does the FC-102P11KT4P55H1XGX1XXSXXXXAXBXCXXXXDX support?

A: This drive supports a mains voltage input of 380 to 480 VAC in three-phase power configurations.

Q: What is the power rating and horsepower of this Danfoss HVAC drive?

A: The FC-102P11KT4P55H1XGX1XXSXXXXAXBXCXXXXDX has a power rating of 11 kW, which equates to 15 horsepower.

Q: What is the protection level provided by the FC-102P11KT4P55H1XGX1XXSXXXXAXBXCXXXXDX?

A: This drive features protection rated at IP55 / Type12 Backplate, offering dust and moderate water resistance.

Q: What type of user interface is included with the FC-102P11KT4P55H1XGX1XXSXXXXAXBXCXXXXDX?

A: The drive includes a graphical local control panel for easy interface and operation.

Q: Does the FC-102P11KT4P55H1XGX1XXSXXXXAXBXCXXXXDX include an RFI filter?

A: It comes equipped with an internal Class A1/B (C1) RFI filter to minimize electromagnetic interference.


Internal Product Review

  • ‘‘The FC-102P11KT4P55H1XGX1XXSXXXXAXBXCXXXXDX is a Danfoss VLT FC 102 HVAC drive with a well-focused configuration for demanding air handling and pumping applications. A 380 to 480 VAC mains range and 11 kW power rating provide solid compatibility for standard three-phase HVAC systems. IP55 / Type 12 backplate protection and a graphical local control panel make this drive especially attractive for practical installation and straightforward setup.’’