4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

FC-102P11KT4E20H1XGXXXXSXXXXAXBXCXXXXDX Danfoss

In-Stock, Ships 3-5 Days

Current response time:
4 Minutes 57 Seconds

Preparing your secure checkout page...

The Danfoss FC-102P11KT4E20H1XGXXXXSXXXXAXBXCXXXXDX is part of the VLT FC 102 HVAC Drives series and supports three-phase power from 380 to 480 VAC. This drive provides a power rating of 11 kW (15 HP) and features cabinet mounting options with an IP20 chassis protection level. It includes a graphical local control panel and a Class A1/B RFI filter.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Danfoss manufactures the FC-102P11KT4E20H1XGXXXXSXXXXAXBXCXXXXDX variable-frequency drive as part of the VLT FC 102 HVAC Drives series. The unit regulates the speed of induction motors used in air-handling units, pumps, and chillers. By adjusting motor output in response to load demand, it allows building automation systems to manage airflow and water flow while reducing unnecessary energy consumption. The drive converts fixed-frequency mains power into a controlled three-phase output for common commercial building services.

The drive provides a continuous output of 11 kW, which corresponds to 15 HP and supports midsized supply fans, return fans, pumps, and chillers. It accepts line power from 380–480 VAC and requires three-phase power. An IP20 chassis enclosure protects against accidental contact with internal components while allowing installation inside a ventilated electrical cabinet or equipment room. The unit has no integrated brake chopper, so applications requiring controlled motor braking must use an external braking arrangement. The configuration includes no mains option, which means preinstalled line-side fuses and disconnects are not included. Plant protection and isolation devices must therefore be selected and installed separately from the drive.

Users operate the drive through a graphical local control panel that attaches to the front of the chassis and displays operating values, menus, and diagnostic information. Standard cable entries provide the physical routing arrangement identified as Adaptation A, allowing power and control wiring to enter the enclosure through the normal access points. An integrated RFI Class A1/B (C1) filter reduces conducted electromagnetic interference and can eliminate the need for a separate line filter in many commercial installations. The controller uses the Standard Language Pack to provide multilingual menu access for setup and operation. Option bays A, B, C0, C1, and D are empty, leaving the corresponding communication and application interfaces unpopulated. Adaptation B is not included in this configuration. The drive uses an uncoated printed circuit board intended for clean, dry cabinet environments where the electronics are not exposed to corrosive airborne contaminants.

A Option
No A Option
Adaptation A
Standard Cable Entries
Adaptation B
No adaptation
B Option
No B Option
Brake - Safe Stop
No brake chopper
C Option Software
No software option
C0 Option MCO
No C0 option
C1 Option
No C1 option
Coating PCB
Not coated PCB
D Option
No D option
Horse Power
15 HP
LCP
Graphical Loc. Cont. Panel
Mains Option
No Mains Option
Mains Voltage
380 - 480 VAC
Mounting
Normal cabinet mounting A, B, C Frames
Power Phase
Three Phase Power
Power Rating
11 KW
Product Group
VLT HVAC Drive
Protection Level
IP20 / Chassis
Rfi Filter
RFI Class A1/B (C1)
Series Identifier
102
Software Language Pack
Standard Language Pack
Software Release
Latest release std. SW.

Frequently Asked Questions about FC-102P11KT4E20H1XGXXXXSXXXXAXBXCXXXXDX:

Q: What is the supported mains voltage range for the FC-102P11KT4E20H1XGXXXXSXXXXAXBXCXXXXDX drive?

A: The FC-102P11KT4E20H1XGXXXXSXXXXAXBXCXXXXDX operates at a mains voltage of 380 to 480 VAC.

Q: What is the maximum horsepower of the FC-102P11KT4E20H1XGXXXXSXXXXAXBXCXXXXDX?

A: This drive offers a maximum power output of 15 horsepower.

Q: What mounting options are available for the FC-102P11KT4E20H1XGXXXXSXXXXAXBXCXXXXDX?

A: The FC-102P11KT4E20H1XGXXXXSXXXXAXBXCXXXXDX supports normal cabinet mounting on A, B, and C frame sizes.

Q: What type of control panel comes with the FC-102P11KT4E20H1XGXXXXSXXXXAXBXCXXXXDX?

A: This model is equipped with a graphical local control panel for user operation.

Q: What protection level is featured on the FC-102P11KT4E20H1XGXXXXSXXXXAXBXCXXXXDX drive?

A: The drive has an IP20 protection level and is provided in a chassis format.


Internal Product Review

  • ‘‘FC-102P11KT4E20H1XGXXXXSXXXXAXBXCXXXXDX is a Danfoss VLT HVAC drive with an 11 kW rating, well suited for precise fan and pump control in building automation. Three-phase 380 to 480 VAC input supports dependable integration across standard facility power systems. The graphical local control panel is a strong addition for fast setup and practical service access.’’