FC-102P110KT4E00H4XGXXX Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-102P110KT4E00H4XGXXX is part of the VLT FC 102 HVAC Drives series and weighs 82 kg. This drive supports a typical shaft output of 110 kW and operates at a supply voltage of 380-500 V AC. It has a rated output current of 190 A at 460/480 V and features an IP00 chassis enclosure with dimensions of 1046 mm in height, 408 mm in width, and 375 mm in depth.
Internal Product Review
The FC-102P110KT4E00H4XGXXX is a Danfoss VLT FC 102 HVAC drive engineered for high-capacity control at 110 kW and 380-500 V AC. An output frequency range of 0-800 Hz and 0.98 efficiency support flexible motor performance with strong energy handling in demanding HVAC applications. IP00/chassis construction and 190 A output current make the drive a capable choice for high-demand panel installations.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-102P110KT4E00H4XGXXX is an AC variable frequency drive produced by Danfoss for the VLT FC 102 HVAC Drives series. It belongs to the VLT HVAC Drive product group and serves building automation systems by modulating induction motor speed in fans, pumps, or compressors to match thermal load demand. The chassis-style IP00 enclosure is intended for integration into a ventilated panel, where cabinet airflow removes heat from the open drive.
This drive operates from a three-phase supply of 380-500 V AC and draws an input current of 183 A at 460/480 V. The inverter section delivers up to 190 A of continuous output to the motor with a programmable frequency range of 0-800 Hz, providing flexibility for constant-torque or variable-torque profiles. A typical shaft power of 110 kW can be reached while the overall conversion efficiency remains at 0.98, reducing heat rejection inside the cabinet. Adaptation A provides standard cable entries, while Adaptation B does not include a special application module. The unit is supplied without a local control panel, so setup and monitoring are handled remotely through a fieldbus or PC tool. Incoming feeders can be protected by a 300 A pre-fuse, and two parallel conductors measuring up to 70 mm² (2/0 AWG) per phase can be connected to the terminals.
During transient loading, the inverter can supply an overload current of 209 A for short intervals, while internal power dissipation is limited to 2947 W at 460 V for enclosure ventilation calculations. The open-chassis unit carries an A1 RFI filter classification for installations in dedicated electrical rooms. The drive measures 1046 mm in height, 408 mm in width, and 375 mm in depth, and the assembly weighs 82 kg for floor or wall mounting. The unit is part of Series 102 and does not include a mains disconnect.