134U7792 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
MPN: FC-102N110T4E21H2XGC7XXSXXXXAJBXCXXXXDX
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss 134U7792 is part of the VLT FC 102 HVAC Drives series and is rated at 150 HP with a power rating of 110 kW. It operates on three phase power at 380 to 480 VAC and has a protection level of IP21. This drive features a graphical local control panel, BACnet MCA 109 option, a coated PCB, and an integrated RFI filter.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 134U7792 is an AC variable frequency drive manufactured by Danfoss within the VLT FC 102 HVAC Drives series. The product belongs to the VLT HVAC Drive group and carries the internal series identifier 102. Installed in motor control panels, it regulates the speed of centrifugal fans, pumps, and compressors used in building ventilation and chilled-water systems. By varying the output frequency, it adjusts motor torque to real-time demand, reducing electrical consumption and mechanical stress in industrial and commercial HVAC installations. This variable-speed operation also reduces the need for mechanical throttling methods, such as dampers and control valves, when the connected equipment operates below its maximum capacity.
Electrical capacity is rated at 110 kW, a continuous power level that corresponds to approximately 150 HP at the motor shaft. The input section accepts utility supplies from 380 to 480 VAC and is designed for three-phase power, allowing connection to standard industrial mains without phase conversion. An enclosure classification of IP21 / Type 1 permits installation in protected indoor areas where limited drip protection is sufficient. The enclosure is intended for dry-room mounting and must be installed where excessive moisture, conductive dust, and direct water exposure are avoided. Standard cable entries under Adaptation A simplify the routing of motor and control wiring through the gland plates. These entries help keep power conductors separated from low-voltage control wiring when the drive is installed in a properly arranged electrical panel.
The drive includes a BACnet MCA 109 communication module for direct integration with compatible building management networks. Local parameter access is provided through a graphical local control panel, which displays operating values, alarms, and configuration menus. Circuit reliability in humid plant rooms is enhanced by coated PCBs that protect the internal electronics from moisture and airborne contaminants. For electromagnetic compatibility, the factory-installed RFI filter attenuates conducted emissions on the mains leads. The B, C1, C0, and D option slots do not contain additional hardware, and Adaptation B is empty. Safe-stop braking hardware is not included, so applications involving regenerative loads require an appropriate external method for controlling returned energy.