132N3949 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
MPN: S102005T6E012CMD2XXSXXZXXGCXXXXXXXXXXXXX
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
6 Minutes
45 Seconds
The Danfoss 132N3949 is part of the VLT FC 102 HVAC Drives series and features a NEMA 1 enclosure with a main disconnect switch. This drive supports a 3-phase input voltage of 600 VAC, has a motor horsepower rating of 5.0 HP, and operates with an input current of 6.3 Amps. It includes a 2 contactor bypass and standard cable entries.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 132N3949 is a variable frequency drive produced by Danfoss for the VLT FC 102 HVAC Drives series. It regulates the speed of three-phase induction motors so air handlers, pumps, and condensers can match actual demand instead of running at fixed line frequency. In building automation, this helps reduce energy use and mechanical wear on fans and compressors while maintaining the airflow or water circulation required by the control system.
The drive mounts in a NEMA 1 housing that protects the internal electronics when installed in mechanical rooms or electrical closets. Its mechanical outline follows frame size A3, which sets the cabinet space and heat-sink dimensions needed for installation. On the mains side, it accepts a 600 VAC supply, draws up to 6.3 A, and is wired for three-phase power at 60 Hz. No reactor or external filter is supplied, so harmonic mitigation must be handled upstream if required. Standard cable entries under Adaptation A simplify conduit routing, and the Safe Stop listing indicates that dynamic braking energy is not dissipated internally. The enclosure also includes a two-contactor bypass assembly that can transfer the motor to the input line when the inverter is isolated for service.
Motor output is rated at 5.0 HP with a continuous full-load current of 6.1 A across the programmable range of 0–60 Hz. The package includes a Main Disconnect so the unit can be isolated before service. There is no local control panel, no C-option, no C1 option board, and no additional mains accessories, so parameter access relies on the standard language pack through fieldbus or PC tools. Because the design uses no internal filter, space inside the A3 frame is not taken up by line-side inductors, which helps keep the assembly compact for HVAC applications.
Frequently Asked Questions about 132N3949:
Q: What input voltage and phase are required for the Danfoss 132N3949 VLT FC 102 HVAC Drive?
A: This drive is designed for operation on a 600 VAC 3-phase electrical supply.
Q: Does the 132N3949 HVAC drive include a disconnect switch?
A: It features a main disconnect switch for isolating the drive from the power supply.
Q: What type of bypass configuration does the Danfoss 132N3949 provide?
A: The drive offers a 2 contactor bypass, allowing for operational flexibility during maintenance or malfunction.
Q: What are the motor FLA and horsepower ratings for the 132N3949 drive?
A: This model has a motor FLA (Full Load Amps) rating of 6.1 A and supports motors rated up to 5.0 HP.
Q: What is the enclosure rating for the Danfoss VLT FC 102 model 132N3949?
A: The enclosure for this drive is rated as NEMA 1, suitable for indoor installation and protection from limited amounts of dust.