The Danfoss 131U0965 is part of the VLT FC 102 HVAC Drives series and operates with three phase power at 380 to 480 VAC. This drive features a graphical local control panel and is equipped with an RFI filter of Class A1/B. Its printed circuit board is not coated.
Internal Product Review
The 131U0965 is a Danfoss VLT FC 102 HVAC drive built for three-phase power on 380 to 480 VAC systems. A graphical local control panel simplifies commissioning, and the RFI Class A1/B (C1) filter supports cleaner integration in HVAC installations. A well-configured drive for stable HVAC control.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 131U0965 variable frequency drive is produced by Danfoss for the VLT FC 102 HVAC Drives series. It is used in industrial and commercial ventilation systems where accurate fan or pump speed control can reduce energy consumption and maintain stable air-handling setpoints. Within an automation system, the drive receives run commands from a building management controller and adjusts motor frequency in response to real-time thermal demand. This control helps maintain programmed airflow, temperature, and pressure levels in heating, ventilation, and air-conditioning equipment.
The power stage accepts a nominal input of 380 to 480 VAC from a three-phase power network, covering common low-voltage supplies found in mechanical rooms. Conducted emissions are attenuated by the integrated RFI Class A1/B (C1) filter, so additional external suppression is generally unnecessary when the drive is installed under suitable operating conditions. Parameters are configured through the front-mounted graphical local control panel, which displays operating status, warnings, and trend data without requiring a separate computer. The circuit boards have an uncoated PCB finish, making the unit suitable for clean, conditioned switchboards rather than areas exposed to corrosive contaminants. The drive does not include A, B, C0, C1, or D expansion options, and it has no separate mains option.
The output stage includes no brake chopper, so a dynamic braking resistor cannot be connected directly to the drive. Applications that require rapid deceleration must account for this limitation through the system design and available motor stopping methods. The software is supplied without application-specific adaptation, while advanced operating functions are selected through the available parameter settings. On-screen text is provided through the Standard Language Pack, giving access to the default selection of supported interface languages. The drive uses the internal series identifier 102, which corresponds to its VLT FC 102 HVAC product classification and supported accessory range.