4.94 based on 222 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

131H1632 Danfoss

In-Stock, Ships 3-5 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The 131H1632 is a Danfoss VLT FC 102 HVAC drive that presents a well-focused solution for controlled building automation duty. Three-phase power with a 380 to 480 VAC mains range supports stable operation, while PROFIBUS DP MCA 101 adds valuable network integration capability. IP20 / chassis protection and normal cabinet mounting make the unit a strong fit for clean, panel-based HVAC installations.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 131H1632 is an AC variable-frequency drive produced by Danfoss for the VLT FC 102 HVAC Drives series. It belongs to the VLT HVAC Drive product group and is intended to regulate the speed of fans, pumps, and compressors in building automation systems. By converting fixed-frequency mains power into a modulated output, the unit provides efficient motor control that can be coordinated with building management networks. Variable-speed operation allows connected equipment to respond to changing airflow, pressure, or temperature demands rather than operating continuously at full speed.

This drive operates from a mains supply of 380–480 VAC through a three-phase power connection, allowing direct connection to typical industrial and commercial distribution panels. The enclosure provides IP20 chassis protection, so the unit must be installed inside a suitable cabinet to prevent exposure to dust, moisture, and unintended contact. Mechanical integration uses normal cabinet mounting for A, B, and C frames, which positions the heat sink for convection within standard HVAC panels. An internal RFI Class A1/B (C1) filter limits conducted emissions and supports compliance with electromagnetic compatibility requirements. No additional mains option is installed. The 102 series identifier provides the parameter structure associated with other FC 102 models, while the standard language pack supplies the interface text needed for system configuration.

Fieldbus connectivity is provided through the A-option slot, which contains a PROFIBUS DP MCA 101 module for exchanging setpoints and status data with compatible PLC networks. Power and control conductors enter through standard cable entries, allowing the wiring to pass into the enclosure without a supplementary cable-entry adapter. The drive uses uncoated circuit boards, making it suitable for installation in dry electrical rooms where conformal protection is not required. The unit has no local control panel, so operating commands and parameter adjustments must be provided through remote tools or the fieldbus connection. A brake chopper is not included, which means regenerative braking energy must be managed by external equipment when the application requires rapid deceleration. The drive also lacks an integrated safe-stop brake function, so any required machine safety functions must be provided elsewhere in the control system.

A Option
PROFIBUS DP MCA 101
Adaptation A
Standard Cable Entries
Adaptation B
No adaptation
B Option
No B Option
Brake - Safe Stop
No brake chopper
C0 Option MCO
No C0 option
C1 Option
No C1 option
Coating PCB
Not coated PCB
D Option
No D option
LCP
No Loc. Cont. Panel
Mains Option
No Mains Option
Mains Voltage
380 - 480 VAC
Mounting
Normal cabinet mounting A, B, C Frames
Power Phase
Three Phase Power
Product Group
VLT HVAC Drive
Protection Level
IP20 / Chassis
RFI Filter
RFI Class A1/B (C1)
Series Identifier
102
Software Language Pack
Standard Language Pack

Frequently Asked Questions about 131H1632:

Q: What type of power phase does the Danfoss 131H1632 VLT FC 102 HVAC Drive support?

A: This drive supports three phase power operation, allowing for greater compatibility with industrial electrical systems.

Q: What mains voltage requirements does the 131H1632 drive have?

A: The 131H1632 is designed for use with a mains voltage range of 380 to 480 VAC, enabling flexible installation in various regions.

Q: Which communication option is included with the Danfoss 131H1632 as the A option?

A: A PROFIBUS DP MCA 101 interface is provided as the A option, allowing for integration into PROFIBUS DP automation networks.

Q: What is the protection level of the Danfoss 131H1632 drive?

A: This model features an IP20 protection level with a chassis configuration for installation in standard cabinet environments.

Q: What kind of RFI filter is included in the 131H1632 VLT FC 102 HVAC Drive?

A: The drive is equipped with an RFI filter rated at Class A1/B (C1) to help minimize electrical interference in sensitive environments.

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo