The Danfoss 131G1419 is a VLT FC 102 HVAC Drive designed for three phase power and for dry room mounting on B, C, D, and E frame sizes. This drive includes a graphical local control panel and has an IP21 / Type 1 protection level. Part of the VLT FC 102 HVAC Drives series, it comes with standard cable entries and no RFI filter installed.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 131G1419 is an AC variable frequency drive produced by Danfoss for the VLT FC 102 HVAC Drives series. The unit converts fixed-frequency mains power into a controlled output that regulates the speed of induction motors used in building ventilation and hydronic systems. By matching motor speed to real-time demand, it improves energy efficiency in air-handling units, chilled-water pumps, and condenser fans found in industrial and commercial facilities. Variable-speed operation also reduces unnecessary mechanical stress caused by continuously running motors at full speed when system demand is low.

Electrical integration requires three-phase power, allowing direct connection to standard 380–480 V feeders. The enclosure carries an IP21 / Type 1 protection rating, guarding against finger contact and vertically dripping water when mounted in conditioned electrical rooms. Local configuration and diagnostics are handled through the graphical local control panel, which presents parameters, trend data, and fault codes without requiring external tools. Because the model has no installed filter, an external RFI filter may be added where conducted-emission limits apply. The unit has standard cable entries that accept metric or NPT glands for power and control conductors, simplifying cable routing within an electrical enclosure.

During deceleration, the controller operates without a brake chopper, so regenerative energy must be absorbed by the load or managed through separate braking equipment. Operator prompts are provided through the standard language pack, making menus and operating messages available in the supported languages. Functional features correspond to the latest standard software release loaded at the factory, supporting compatibility with current drive tools and control functions. Its classification in the VLT HVAC Drive product group provides predefined application macros for supply fans, return fans, and variable-primary pumping systems. These macros support closed-loop pressure or temperature control while reducing the amount of custom parameter entry required for common HVAC applications.

A Option
No A Option
Adaptation A
Standard Cable Entries
Adaptation B
No adaptation
B Option
No B Option
Brake - Safe Stop
No brake chopper
C Option Software
No software option
C0 Option MCO
No C0 option
C1 Option
No C1 option
Coating PCB
Not coated PCB
D Option
No D option
LCP
Graphical Loc. Cont. Panel
Mains Option
No Mains Option
Mounting
For dry room mounting B , C, D, and E Frame
Power Phase
Three Phase Power
Product Group
VLT HVAC Drive
Protection Level
IP21 / Type 1
RFI Filter
No Filter Installed
Series Identifier
102
Software Language Pack
Standard Language Pack
Software Release
Latest release std. SW.

Frequently Asked Questions about 131G1419:

Q: What type of power phase does the Danfoss 131G1419 VLT FC 102 HVAC Drive support?

A: The 131G1419 is designed for three phase power input, making it suitable for use with three-phase electrical systems.

Q: What kind of user interface is available on the 131G1419 drive?

A: This model features a graphical local control panel for convenient on-site configuration and monitoring.

Q: What protection level does the 131G1419 HVAC drive have?

A: The 131G1419 drive provides IP21 / Type 1 protection, which helps shield internal components from solid objects and limited moisture.

Q: Does the Danfoss 131G1419 drive include a brake chopper?

A: No brake chopper is present in the 131G1419, so it does not support internal braking functions.

Q: What are the mounting requirements for the 131G1419 VLT FC 102 drive?

A: The 131G1419 is intended for dry room mounting and is compatible with frames B, C, D, and E.


Internal Product Review

  • ‘‘The 131G1419 is a Danfoss VLT FC 102 HVAC drive designed for three-phase power and equipped with a graphical local control panel. IP21 / Type 1 protection and dry-room mounting support clean cabinet integration in building automation environments. A strong choice for HVAC control where straightforward setup and dependable drive operation are priorities.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo