The Danfoss 131F3370 is part of the VLT FC 102 HVAC Drives series and features a power rating of 15 kW or 20 horsepower. This drive operates on a three-phase 380-480 VAC mains voltage and has an IP55 / Type 12 protection level. It comes equipped with a graphical local control panel and includes an RFI filter.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 131F3370 is a variable-frequency drive manufactured by Danfoss for the VLT FC 102 HVAC Drives series. It converts constant-frequency mains power into a modulated electrical output that regulates the speed of fans, pumps, and compressors in building automation systems. Closed-loop control allows the drive to adjust motor speed in response to changing airflow, pressure, or temperature demands. This operating method can reduce unnecessary energy consumption when connected equipment does not need to run at full speed.

Rated motor output reaches 20 HP, corresponding to a continuous electrical capacity of 15 kW at the motor terminals. The drive accepts a supply range of 380–480 VAC and uses three-phase power, allowing direct connection to standard industrial distribution systems within that voltage range. Its IP55 / Type 12 enclosure protects internal components from dust and splashed liquids. This protection supports installation in mechanical equipment rooms where airborne particles or occasional moisture may be present. The unit does not include a brake chopper, so regenerated energy produced by a rapidly decelerating motor must be managed through suitable external equipment when necessary. Its electrical design is intended for HVAC loads, which commonly use gradual acceleration and deceleration rather than frequent dynamic braking.

Control wiring enters through standard cable entries, providing an organized route for field wiring and control conductors. The printed circuit boards are uncoated and are intended for serviceable indoor environments without severe moisture or corrosive airborne contaminants. Operator interaction is provided through a graphical local control panel, which gives users access to operating values, settings, alarms, and drive status. Parameters are presented through a Standard Language Pack, making menus and operating information available in the supported standard languages. Conducted electrical emissions are reduced by an integrated RFI filter, helping the drive meet common electromagnetic compatibility requirements for building services. The filter also limits high-frequency interference transmitted from the drive to the connected power network, reducing its effect on nearby electrical equipment.

A Option
No A Option
Adaptation A
Standard Cable Entries
Adaptation B
No adaptation
B Option
No B Option
Brake - Safe Stop
No brake chopper
C0 Option MCO
No C0 option
C1 Option
No C1 option
Coating PCB
Not coated PCB
D Option
No D option
Horse Power
20 HP
LCP
Graphical Loc. Cont. Panel
Mains Voltage
380 - 480 VAC
Power Phase
Three Phase Power
Power Rating
15 KW
Product Group
VLT HVAC Drive
Protection Level
IP55 / Type 12
RFI Filter
RFI Filter
Series Identifier
102
Software Language Pack
Standard Language Pack

Frequently Asked Questions about 131F3370:

Q: What is the power rating of the Danfoss 131F3370 drive?

A: The 131F3370 VLT FC 102 supports a power rating of 15 kW, suitable for sizeable HVAC applications.

Q: What mains voltage is required for the 131F3370 VLT FC 102 drive?

A: This drive operates on a mains voltage range of 380 - 480 VAC for flexible integration with various power supplies.

Q: What type of local control panel is equipped on the 131F3370 drive?

A: The Danfoss 131F3370 provides a graphical local control panel for user-friendly on-site operation and monitoring.

Q: What power phase configuration does the 131F3370 support?

A: It is designed for three-phase power, making it compatible with industrial and commercial electrical systems.

Q: What is the protection level of the Danfoss 131F3370 VLT FC 102 drive?

A: The 131F3370 features IP55 / Type 12 protection, offering resistance to dust and water for enhanced durability.


Internal Product Review

  • ‘‘The 131F3370 is a Danfoss VLT HVAC drive rated at 15 kW for 380 - 480 VAC service. Three-phase power input and IP55 / Type 12 protection make the unit well suited for demanding HVAC installations with stable drive performance. The graphical local control panel adds practical commissioning value, and the integrated RFI filter stands out as a strong final feature.’’