4.95 based on 202 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

131B5661 Danfoss

In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Danfoss 131B5661 is part of the VLT FC 102 HVAC Drives series and operates on three-phase power with a mains voltage range of 380 to 480 VAC. This drive features a graphical local control panel, RFI Class A1/B filter, and carries an IP55/Type12 backplate protection level.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 131B5661 variable-frequency drive is produced by Danfoss and belongs to the VLT FC 102 HVAC Drives series. It modulates the output frequency supplied to centrifugal fans, pumps, and compressors, allowing building-management systems to match motor speed to real-time heating, cooling, and ventilation demand. The unit integrates motor control, equipment protection, and a user interface in one enclosure for use in industrial and commercial air-handling installations. Adjusting motor speed according to demand can reduce unnecessary energy consumption compared with applications that operate motors continuously at full speed.

The drive accepts 380–480 VAC from a three-phase power supply, allowing direct connection to standard industrial mains. Its IP55 / Type 12 backplate enclosure protects the internal electronics from dust and water jets when the unit is installed correctly. Conducted emissions are limited by the built-in RFI Class A1/B (C1) filter, helping nearby electrical equipment comply with applicable electromagnetic compatibility limits. Parameter entry and fault logging are handled through a detachable graphical local control panel, which presents operating values and status information on a backlit screen. The heat sink is attached to a backplate designed for Frame A5, B, and C units. Airflow across the open rear of the drive removes heat without requiring additional ductwork.

Cables enter through standard cable entries, providing an uncomplicated path for mains, motor, and control wiring. The standard backplate geometry is retained because the unit does not include a backplate adaptation. Motor stopping relies on drive control because the DC bus has no brake chopper for an external braking resistor. The control board uses an uncoated printed circuit board, making the drive suitable for clean HVAC equipment rooms where moisture and corrosive contaminants are controlled. The unit does not include auxiliary option boards, motion cards, an additional C1 filter, or an integrated mains switch. Its interface uses the standard language pack for menu navigation and operating messages. The internal 102 identifier associates the drive with other products in the VLT HVAC Drive group without changing its electrical installation requirements.

A Option
No A Option
Adaptation A
Standard Cable Entries
Adaptation B
No adaptation
B Option
No B Option
Brake - Safe Stop
No brake chopper
C0 Option MCO
No C0 option
C1 Option
No C1 option
Coating PCB
Not coated PCB
D Option
No D option
LCP
Graphical Loc. Cont. Panel
Mains Option
No Mains Option
Mains Voltage
380 - 480 VAC
Mounting
Frame A5, B & C Backplate for open Drive back
Power Phase
Three Phase Power
Product Group
VLT HVAC Drive
Protection Level
IP55 / Type12 Backplate
RFI Filter
RFI Class A1/B (C1)
Series Identifier
102
Software Language Pack
Standard Language Pack

Frequently Asked Questions about 131B5661:

Q: What is the mains voltage range for the Danfoss 131B5661 drive?

A: The VLT FC 102 HVAC Drive 131B5661 operates with a mains voltage of 380 - 480 VAC suitable for commercial building HVAC systems.

Q: What type of power phase does the 131B5661 support?

A: This drive is designed to handle three phase power input, making it suitable for industrial and commercial environments.

Q: What protection level does the Danfoss 131B5661 provide?

A: The 131B5661 is built with IP55 / Type12 backplate protection, ensuring dust and water resistance for reliable operation in varied conditions.

Q: What type of control panel is included with the 131B5661?

A: The graphical local control panel (LCP) allows users to access settings and operate the drive visually through intuitive menus.

Q: What RFI filter classification does the Danfoss 131B5661 use?

A: The 131B5661 comes with an RFI filter rated for Class A1/B (C1), helping to reduce electromagnetic interference in installations.


Internal Product Review

  • ‘‘The 131B5661 is a Danfoss VLT HVAC drive designed for three-phase power at 380 to 480 VAC. The graphical local control panel and RFI Class A1/B (C1) filtering support straightforward setup and clean integration in HVAC panels. IP55 / Type 12 backplate protection makes the unit a strong choice for dependable HVAC drive service.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo