The Danfoss 131B1273 is part of the VLT FC 102 HVAC Drives series and features a power rating of 11 kW, with a maximum output of 15 HP. It is designed for three phase power operation at 380 to 480 VAC, and uses a graphical local control panel for user interface. This HVAC drive features an IP21 / Type 1 protection level and comes with an RFI filter rated for Class A1/B (C1).

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 131B1273 is an AC variable frequency drive produced by Danfoss for the VLT FC 102 HVAC Drives series. It converts constant-frequency, three-phase mains power into a modulated output that allows building automation systems to regulate motor speed. This variable-speed operation is suitable for supply fans, return fans, pumps, and chillers that must respond to changing heating or cooling demand. Matching motor output to the required airflow or fluid flow can reduce unnecessary energy consumption compared with constant-speed operation.

The drive delivers a continuous mechanical output of 11 kW, which corresponds to 15 HP. It accepts an input supply ranging from 380–480 VAC, making it suitable for common industrial and commercial electrical distribution systems. The unit operates with three-phase power and therefore connects directly to a compatible three-phase supply without phase conversion equipment. Its IP21 / Type 1 enclosure prevents accidental finger contact with internal components and protects the electronics from vertically falling water drops. This enclosure is intended for dry indoor installation using the applicable B, C, D, or E frame arrangement. Standard cable entries support routine power and control wiring, while the uncoated printed circuit boards are intended for locations without unusually corrosive airborne contaminants. The unit does not contain a brake chopper, which is generally unnecessary for fan and pump loads that do not require rapid regenerative braking.

An integrated RFI Class A1/B (C1) filter limits conducted electromagnetic emissions and can reduce the need for separate filtering components in compatible installations. Local operation is provided through a detachable graphical local control panel with a backlit display for viewing parameters, operating values, alarms, and trend data. The multilingual VLT HVAC Drive language pack presents menu information in supported languages and uses terminology associated with the FC 102 platform. The panel can be removed when direct local access is not required, while the drive remains available for control through the connected building automation system. Field-installable accessories can be added when later system changes require additional communication or control functions.

A Option
No A Option
Adaptation A
Standard Cable Entries
Adaptation B
No adaptation
B Option
No B Option
Brake - Safe Stop
No brake chopper
C Option Software
No software option
C0 Option MCO
No C0 option
C1 Option
No C1 option
Coating PCB
Not coated PCB
D Option
No D option
Horse Power
15 HP
LCP
Graphical Loc. Cont. Panel
Mains Option
No Mains Option
Mains Voltage
380 - 480 VAC
Mounting
For dry room mounting B , C, D, and E Frame
Power Phase
Three Phase Power
Power Rating
11 KW
Product Group
VLT HVAC Drive
Protection Level
IP21 / Type 1
RFI Filter
RFI Class A1/B (C1)
Series Identifier
102
Software Language Pack
Standard Language Pack
Software Release
Latest release std. SW.

Frequently Asked Questions about 131B1273:

Q: What is the power rating of the 131B1273 VLT FC 102 HVAC Drive?

A: The Danfoss 131B1273 VLT FC 102 HVAC Drive provides a power rating of 11 kW for efficient operation of HVAC systems.

Q: What power phase and voltage does the 131B1273 drive support?

A: This drive is suitable for three-phase power connections and operates on a mains voltage range from 380 to 480 VAC.

Q: What type of control panel does the 131B1273 drive include?

A: The 131B1273 features a graphical local control panel for user interface and configuration.

Q: What is the protection level of the 131B1273 VLT FC 102?

A: Protection level is rated at IP21 / Type 1, making it suitable for indoor, dry room mounting.

Q: What type of RFI filter is included with the 131B1273 drive?

A: This Danfoss VLT FC 102 drive includes an RFI filter rated at Class A1/B (C1) to minimize radio frequency interference.


Internal Product Review

  • ‘‘The 131B1273 is a Danfoss VLT FC 102 HVAC drive engineered for stable building automation duty, with a 15 HP rating and 380 - 480 VAC input. Three-phase power architecture and an IP21 / Type 1 enclosure support dependable installation in dry-room HVAC panels. A graphical local control panel adds practical commissioning value, making the package a strong choice for precise HVAC drive service.’’