FC-301PK75T2134H7538 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss FC-301PK75T2134H7538 is part of the VLT FC 301 Automation Drives series and has a power rating of 0.75 kW with a horsepower of 1.0 HP. It supports three phase 200-240 VAC mains voltage with a continuous output current of 4.6 Amps and delivers an efficiency of 0.95 at rated current. This drive offers one 12-bit analog output, two digital pulse outputs, and can operate at a maximum output frequency of 590 Hz.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301PK75T2134H7538 is a variable frequency drive manufactured by Danfoss as part of the VLT FC 301 Automation Drives series. The controller converts fixed-frequency mains power into a regulated output for controlling induction motors. This regulation allows the drive to adjust motor speed, synchronize torque, and reduce energy consumption in automated conveyors, pumps, and fan arrays. Its FC 301 format shares mechanical dimensions with related drives in the product group, supporting installation in distributed control panels on factory floors.
The drive delivers 0.75 kW of continuous shaft power, which corresponds to 1.0 HP. It operates on three-phase power and accepts line voltages from 200–240 VAC, drawing 4.1 A while producing a continuous output of 4.6 A. The resulting apparent power at 230 V is 1.83 kVA. Efficiency reaches 0.95 at rated current, so only a small portion of the input energy becomes heat. One analog output with 12-bit resolution is provided for transmitting a proportional control or monitoring signal. Two digital pulse outputs can operate counters at frequencies up to 32 kHz, providing additional connectivity for automated equipment.
Flux regulation is maintained at frequencies up to 300 Hz, while the synthesized output can extend to 590 Hz for high-speed machining or blower applications. Terminal voltage follows the input and can rise to 100% of the supply voltage. The transistor driver section provides 40 mA of sourcing capability for external relays or optoisolators. Internal power losses are limited to 54 W at rated load, which reduces the amount of heat that must be removed from the panel. Shielded motor leads may reach 50 m, while unshielded leads may extend to 75 m. These permitted cable lengths provide routing flexibility while helping the drive maintain electromagnetic compatibility in industrial installations.