FC-301PK37T2134L2961 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-301PK37T2134L2961 is part of the VLT FC 301 Automation Drives series and offers a power rating of 0.37 kW with 0.50 HP. It operates on three phase power with a mains voltage range of 200 to 240 VAC and has a rated output current of 2.40 Amps. This drive features an efficiency of 0.94 at rated current and supports an output frequency up to 590 Hz.
Internal Product Review
The FC-301PK37T2134L2961 is a Danfoss VLT FC 301 automation drive built for precise motor control on 200 to 240 VAC three-phase power. A rated output current of 2.40 A and 0.94 efficiency at rated current give this unit impressively efficient performance in light-duty automation service. Support for output frequencies up to 590 Hz makes this drive a strong option for responsive speed regulation.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301PK37T2134L2961 is an AC variable frequency drive produced by Danfoss for the VLT FC 301 Automation Drives series. The controller regulates the speed of induction motors used in conveyors, pumps, and general process machinery. It is designed for three-phase power networks and uses the internal 301 series identifier. The drive converts fixed-frequency mains power into a variable-frequency output for closed-loop automation tasks, allowing connected motors to respond accurately to changing process commands and operating conditions.
The motor output is rated at 0.50 HP, which corresponds to a continuous electrical power rating of 0.37 kW at the motor terminals. The inverter accepts a line supply of 200–240 VAC and delivers up to 2.40 A of phase current while maintaining speed control at output frequencies up to 590 Hz. Under rated load, the front end draws 2.20 A, while the current input has a resistance of 200 Ω and the voltage input has a resistance of 10 kΩ. At 208 V, the apparent power requirement is 0.86 kVA. The drive can energize external control circuits through a 10 V reference that supplies up to 15 mA and a 24 V service output rated at 200 mA. Shielded motor cables may extend to 50 m, while unshielded motor cables may extend to 75 m.
At 230 V, the converter draws an apparent power of 0.96 kVA and dissipates 29 W at maximum load, so normal panel airflow is generally sufficient for heat removal. Its electrical efficiency is 0.94, which limits conversion losses during continuous-duty operation. The supply can tolerate a phase imbalance of up to 3.0% before protective shutdown, providing operating tolerance for uneven power distribution on lower-power feeders. Breakers and filters should be selected according to the stated input demand, while enclosure ventilation should account for the heat dissipated under maximum load.