FC-301PK37T2134L2894 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-301PK37T2134L2894 is part of the VLT FC 301 Automation Drives series and operates with a power rating of 0.37 kW and 0.50 HP. This drive supports three phase power with a mains voltage range of 200 to 240 VAC and a supply frequency of 50/60 Hz. It has a maximum input current of 2.2 A and offers an output frequency range from 0 to 590 Hz.
Internal Product Review
The FC-301PK37T2134L2894 is a Danfoss VLT FC 301 automation drive rated at 0.37 kW with a 200–240 VAC input range. Three-phase power and output frequency up to 590 Hz give the drive excellent flexibility for precise motor control. A 160% overload class for 1 min/10 min makes the unit a strong choice for dependable light-duty automation service.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301PK37T2134L2894 is an AC variable frequency drive manufactured by Danfoss for the VLT FC 301 Automation Drives series. The unit sits between the utility supply and a three-phase induction motor, modulating both voltage and frequency to regulate shaft speed. In material-handling cells, pump stations, or HVAC systems, this control method helps maintain consistent process variables, reduce mechanical stress, and improve overall electrical efficiency within automated installations.
It handles an apparent power of 0.96 kVA at 230 V, indicating the combined real and reactive load that the upstream breaker must accommodate. A conversion efficiency of 0.94 means that only about 6 percent of the incoming energy becomes heat, easing cabinet cooling requirements. With a continuous mechanical capacity of 0.50 HP, which corresponds to 0.37 kW, the inverter is suitable for fractional-horsepower machinery such as small conveyors or mixers. Its rectifier accepts line voltages within the 200–240 VAC range and draws up to 2.2 A at peak demand. The synthesized output can range from zero to 590 Hz, allowing a four-pole motor to run above its base speed when higher process throughput is required. Output voltage tracks the selected frequency from 0 to 100 percent of the supply voltage, and the rated load current is 2.4 A across all three phases.
To absorb intermittent load spikes, the drive tolerates 160% for 1 minute every 10 minutes before thermal or current limits intervene. The internal DC bus triggers an overvoltage alarm at 410 V DC, allowing the control system to manage regenerative events or use slower deceleration ramps. Continuous operation dissipates only 29 W, so most enclosures require minimal airflow. The electronics maintain a true power factor of at least 0.9 and support supply frequencies of 50 or 60 Hz with a variation of ±5 percent. Motor leads may be up to 50 m long when shielded or 75 m long when unshielded. Flux mode extends torque production from 0 to 300 Hz without requiring external feedback.