FC-301PK25T2134L2960 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss FC-301PK25T2134L2960 is part of the VLT FC 301 Automation Drives series and operates on three phase 200 to 240 VAC mains voltage. It has a power rating of 0.25 kW, an efficiency of 0.94, and a rated output current of 1.80 A. The drive features a maximum digital input voltage of 28 V DC with a short-circuit current rating of 100000 A RMS.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301PK25T2134L2960 is a variable-frequency drive produced by Danfoss for the VLT FC 301 Automation Drives series. It receives three-phase mains power, synthesizes a new frequency, and supplies induction or permanent-magnet motors so that machine builders can control shaft speed without throttling mechanical components. Its electronic speed control supports low-power conveyors, compact pumps, and other automated devices that require precise process regulation. The drive can adjust motor operation in response to changing load demands, reducing unnecessary mechanical stress and improving control over acceleration and deceleration.
The input section accepts a supply of 200–240 VAC and draws up to 0.72 kVA at 230 V, while the power stage delivers a mechanical output of 0.33 HP. At full load, the converter has an efficiency of 0.94, so only 21 W of its throughput becomes heat that must be removed from the enclosure. The rectifier and DC link keep reactive demand low, resulting in a displacement factor above 0.98 and a true power factor of at least 0.9. Maximum input current is limited to 1.6 A, protecting upstream breakers during steady operation, and phase imbalance must remain within 3.0% to prevent overcurrent trips. Control terminals tolerate 28 V DC on the digital inputs, while the safe torque off circuit draws 50 mA RMS at 24 V when active. No more than two power-ups per minute are permitted, allowing the inrush limiter to cool between energizations.
The inverter output can continuously supply 1.80 A through shielded motor cable runs up to 50 m long. An internal monitor raises an alarm if the DC bus exceeds 410 V DC, helping protect the power stage from excessive voltage. The drive has a short-circuit current rating of 100,000 A RMS, which supports installation on appropriately protected industrial power systems. Its control and protection functions allow apparent-power fluctuations without nuisance trips during normal operation. Proper cable shielding also helps limit electrical interference between the motor circuit and nearby control wiring.