The Danfoss FC-301P75KT4131H3773 is part of the VLT FC 301 Automation Drives series and operates on three phase power with a rated power of 0.75 kW. It accepts 380-480 VAC mains voltage and features an integrated EMC RFI filter. The drive achieves an efficiency of 0.96 at rated current and supports a maximum output frequency of 590 Hz.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-301P75KT4131H3773 is an AC variable frequency drive manufactured by Danfoss for the VLT FC 301 Automation Drives series. Housed within the VLT AutomationDrive FC product group, the unit processes three-phase power to supply adjustable voltage and frequency to induction motors used in conveyors, pumps, and ventilation fans. This conversion allows precise speed control while maintaining process stability in industrial automation. The drive can regulate motor speed in response to changing process demands, reducing unnecessary mechanical output during partial-load operation. Its three-phase architecture supports common industrial motor applications that require controlled acceleration, deceleration, and continuous speed adjustment.

Electrical performance centers on a rated output of 0.75 kW, delivered when the drive is supplied with an input of 380–480 VAC. The inverter can generate a carrier-limited output frequency of up to 590 Hz, while a flux-mode ceiling of 300 Hz supports field-weakening operation at high motor speeds. Full-load efficiency reaches 0.96, consistent with the IE2 energy-efficiency class, and the displacement power factor exceeds 0.98; the true power factor is at least 0.9. Input phase imbalance must remain below 3.0% to prevent excessive stress on the DC link. The RFI section includes an integrated EMC filter that reduces conducted emissions on the mains supply. Operation is limited to two power-ups per minute so that the inrush-current components have adequate time to cool between starts.

The control platform accepts temporary overloads of 160% for 1 minute per 10 minutes, enabling acceleration of high-inertia loads without requiring a larger enclosure. Continuous current is available up to an ambient temperature of 45 °C, while operation below 0 °C requires cabinet heating. Installation at altitudes up to 1000 m requires no derating, after which the available thermal margin decreases. Power loss at rated load is limited to 46 W, which reduces the ventilation demand inside the control panel. The protective design meets overvoltage category III requirements for industrial distribution systems. These protections allow the drive to operate on typical factory power networks while helping shield its internal circuits from transient voltage conditions.

Displacement Power Factor
>0.98
Efficiency At Rated Current
0.96
Energy Efficiency Class
IE2
Flux Mode Frequency
300 Hz
Intermittent Overload
160% / 1 min per 10 min
Mains Voltage
380 - 480 VAC
Max Altitude No Derating
1000 m
Max Ambient Full Current
45 °C
Max Output Frequency
590 Hz
Max Phase Imbalance
3.0%
Max Power-ups
2/min
Min Ambient Full Scale
0 °C
Overvoltage Category
III
Power Loss At Rated Load
46 W
Power Phase
Three Phase Power
Product Group
VLT AutomationDrive FC
Rated Power
0.75 kW
RFI Filter
Integrated EMC filter
Series Identifier
301
True Power Factor
≥0.9

Frequently Asked Questions about FC-301P75KT4131H3773:

Q: What is the rated power output of the FC-301P75KT4131H3773 drive?

A: The FC-301P75KT4131H3773 operates at a rated power of 0.75 kW.

Q: What mains voltage range does the FC-301P75KT4131H3773 support?

A: This model accepts a mains voltage range from 380 to 480 VAC for versatile installation.

Q: Does the FC-301P75KT4131H3773 drive include an RFI or EMC filter?

A: It features an integrated EMC RFI filter for electromagnetic compatibility.

Q: What is the maximum output frequency of the FC-301P75KT4131H3773 drive?

A: The maximum output frequency for this drive is 590 Hz, enabling high-speed motor control.

Q: What is the maximum ambient temperature for full current operation of the FC-301P75KT4131H3773?

A: This drive maintains full current operation at ambient temperatures up to 45 °C.


Internal Product Review

  • ‘‘The FC-301P75KT4131H3773 is a Danfoss VLT FC 301 automation drive designed for three-phase power on 380 to 480 VAC mains. Rated efficiency of 0.96 and displacement power factor above 0.98 support very strong electrical performance in automation service. The 160% intermittent overload capacity for 1 minute per 10 minutes is a valuable operating advantage.’’