4.94 based on 219 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

FC-301P75KT4131B6119 Danfoss

Ask for Availability

Preparing your secure checkout page...

The Danfoss FC-301P75KT4131B6119 is a drive from the VLT FC 301 Automation Drives series with a rated power of 75 kW. It operates on three phase power at a mains voltage of 380 to 480 VAC and supports a maximum output frequency of 590 Hz. The drive offers a normal overload current of 177 A at 380 to 440 V and supports shielded motor cable lengths up to 50 meters.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-301P75KT4131B6119 is a variable speed AC drive manufactured by Danfoss and included in the VLT FC 301 Automation Drives series. Installed upstream of three-phase motors, the converter adjusts output voltage and frequency to match load demands, allowing precise speed control in conveyors, centrifugal pumps, and material-handling systems. By converting fixed-frequency mains into a programmable waveform, it supports energy-efficient operation and lowers mechanical stress on driven equipment. Built-in control functions let the drive regulate acceleration, deceleration, and steady-state speed so process equipment can respond smoothly to changing loads.

Electrically, the drive draws three-phase power across a nominal range of 380 – 480 VAC and can supply mechanical loads up to 75 kW. This operating range makes the unit suitable for common industrial distribution systems used with standard induction motors. The inverter reproduces up to 100% of the input voltage while extending the output frequency ceiling to 590 Hz, and flux-optimization functions remain active through 300 Hz for field-oriented control. For short-term starting or braking, the current limit rises to 177 A @ 380–440 V, and the intermediate DC link issues an alarm if it reaches 820 V DC. To protect the power stage, only one energization cycle per minute is permitted at 1/min. Control terminals tolerate logic levels to 28 V DC, and the safe-torque-off circuit sinks 50 mA rms when engaged. The control stage also accepts external run, stop, and reference signals for integration with machine-level controls. It also maintains a true power factor of ≥0.9 while supporting unshielded motor leads up to 75 m.

High-frequency switching performance is confirmed by a maximum carrier pulse rate of 110 kHz, enabling fine resolution in current regulation and reduced motor acoustic noise. This behavior can improve speed stability in applications that require quiet operation at varying loads. When shielded conductors are required for EMC compliance, the drive supports cable runs up to 50 m. Overall input quality remains strong, with a displacement power factor better than >0.98, minimizing reactive demand on the plant supply.

Displacement Power Factor
>0.98
Mains Voltage
380 - 480 VAC
Max Digital Input Voltage
28 V DC
Max Flux Frequency
300 Hz
Max Output Frequency
590 Hz
Max Output Voltage
100% of supply
Max Power-ups
1/min
Max Pulse Frequency
110 kHz
Normal Overload Current
177 A @ 380–440 V
Overvoltage Alarm
820 V DC
Power Phase
Three Phase Power
Product Group
VLT AutomationDrive FC
Rated Power
75 kW
Series Identifier
301
Shielded Motor Cable
50 m
Sto Input Current
50 mA rms
True Power Factor
≥0.9
Unshielded Motor Cable
75 m

Frequently Asked Questions about FC-301P75KT4131B6119:

Q: What is the mains voltage range supported by the Danfoss FC-301P75KT4131B6119 drive?

A: The FC-301P75KT4131B6119 operates with a mains voltage range of 380 to 480 VAC.

Q: What is the rated power of the FC-301P75KT4131B6119 Automation Drive?

A: This model delivers a rated power output of 75 kW for high-capacity applications.

Q: What is the maximum output frequency of the FC-301P75KT4131B6119?

A: The maximum output frequency of this drive is 590 Hz, allowing for flexible motor speed control.

Q: What is the normal overload current rating for the Danfoss FC-301P75KT4131B6119 at 380–440 V?

A: The normal overload current is 177 A when operated at 380–440 V.

Q: What is the maximum allowable shielded motor cable length for the FC-301P75KT4131B6119?

A: It supports a shielded motor cable length of up to 50 meters for proper installation.


Internal Product Review

  • ‘‘The FC-301P75KT4131B6119 is a Danfoss VLT FC 301 automation drive rated at 75 kW for 380 to 480 VAC systems. Three-phase power operation and output frequency up to 590 Hz give this unit excellent range for demanding motor control applications. A displacement power factor above 0.98 stands out as a strong efficiency advantage.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo