FC-301P5K5T4131X9038 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-301P5K5T4131X9038 is part of the VLT FC 301 Automation Drives series and offers a power rating of 5.5 kW with a horse power of 7.5 HP. Designed for three phase power and mains voltages from 380 to 480 VAC, it features an overload capacity of 160% with a duty cycle of 1 minute per 10 minutes. The drive provides a short-circuit rating of 100000 A RMS and supports both shielded and unshielded motor cables up to 50 m and 75 m respectively.
Internal Product Review
The FC-301P5K5T4131X9038 is a Danfoss VLT FC 301 automation drive rated at 5.5 kW and 7.5 HP. Three-phase operation across 380 to 480 VAC and 160% overload capacity support dependable motor control in demanding applications. High input quality with a displacement power factor above 0.98 makes this unit an efficient and well-balanced drive choice.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301P5K5T4131X9038 is an AC variable frequency drive produced by Danfoss within the VLT FC 301 Automation Drives series. The product converts fixed-frequency, three-phase mains power into modulated voltage and frequency, allowing PLCs to regulate induction motor torque and speed in conveyor, pump, and fan applications. By incorporating fieldbus connectivity and drive-based control functions, it provides a compact method for integrating closed-loop motion into general industrial automation systems.
The rated output power is 5.5 kW, and the input section accepts a supply range of 380–480 VAC. At 400 V, the inverter draws up to 9.0 kVA, producing a displacement power factor above 0.98 and a true power factor of at least 0.9, which eases transformer sizing. The drive can withstand 160% of the nominal load for one minute in every ten, providing a margin for acceleration or momentary process peaks. Protection logic also monitors a 3.0% phase imbalance limit and prevents further energization when more than two power-ups per minute are detected. Control I/O includes an analog feedback channel with an accuracy of 0.5% FS and a digital transistor output rated at 40 mA for direct actuation of external indicators.
The inverter can withstand fault currents up to 100,000 A RMS, so it can be connected to feeders protected by high-capacity circuit breakers. For applications using imperial units, it provides 7.5 HP of continuous motor power while drawing 8.8 kVA from a 460 V mains supply. The digital terminal can switch at 32 kHz, enabling high-speed counting or fine-resolution pulse-width modulation for external devices. Cabinet layouts may include up to 50 m of shielded motor cable without exceeding the permitted voltage rise limits at the motor. When unshielded cable is used, the maximum permitted motor cable length increases to 75 m, providing additional routing flexibility in larger machine installations.