FC-301P5K5T2134L2902 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-301P5K5T2134L2902 is part of the VLT FC 301 Automation Drives series and supports a power rating of 5.5 kW with three phase power. This drive handles continuous output of 24.2 A and is designed for mains voltage between 200 and 240 VAC. It offers a maximum output frequency of 590 Hz and supports cable sizes up to 10 mm².
Internal Product Review
The Danfoss FC-301P5K5T2134L2902 is a VLT FC 301 automation drive rated at 5.5 kW and 7.5 HP. Three-phase 200 to 240 VAC input and 24.2 A continuous output current support stable performance in demanding motion and process applications. A 160% overload rating for 1 min/10 min makes the unit a strong choice for dependable drive service.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301P5K5T2134L2902 variable frequency drive is produced by Danfoss for the VLT FC 301 Automation Drives series. As a Series 301 model in the VLT AutomationDrive FC product group, it converts fixed three-phase power into adjustable voltage and frequency for induction motors used on conveyors, pumps, and material-handling axes. Its compact dimensions and integrated control terminals allow direct panel mounting in distributed automation cabinets. Parameters can be adjusted through a front keypad or optional fieldbus modules, while standard analog interfaces accommodate external command signals. This arrangement supports local configuration at the panel as well as remote control through a compatible automation network.
The unit operates from a three-phase supply of 200–240 VAC and delivers up to 5.5 kW to connected machinery. During steady operation, it draws 22 A and supplies 24.2 A to the motor. The analog command input has an impedance of 4 kΩ, and the control board provides up to 40 mA through its digital output. Drive braking uses a 390 V DC link to manage regenerated energy during motor deceleration. Field excitation reaches 300 Hz, while the maximum output frequency is 590 Hz. The drive supports a 160% overload for 1 minute in each 10-minute interval. Power-up cycles should be limited to two per minute to reduce stress on the DC-link capacitors.
The protection system raises an overvoltage alarm when the DC link reaches 410 V DC. Internal power losses total 239 W during steady operation, so cabinet airflow must remove the resulting heat. The inverter accepts power conductors with cross-sectional areas up to 10 mm², providing sufficient capacity for the rated input and output currents. Electromagnetic compatibility is maintained when shielded motor cables are limited to 50 m. The installation should retain the required three-phase topology to maintain balanced current across the input conductors. Proper cable shielding and routing also help reduce conducted and radiated electrical interference near control wiring. The drive is suitable for medium-capacity pumps, fans, compressors, conveyors, and material-handling equipment that require adjustable motor speed.