FC-301P5K5T2134L2671 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss FC-301P5K5T2134L2671 is part of the VLT FC 301 Automation Drives series and supports three phase power with a main voltage range of 200 to 240 VAC. This drive has a power rating of 5.5 kW, a maximum input current of 22 A, and supports horse power up to 7.5 HP. It features a 12-bit analog output resolution and a rated output current of 24.2 A.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301P5K5T2134L2671 is an AC variable frequency drive produced by Danfoss for the VLT FC 301 Automation Drives series within the VLT AutomationDrive FC product group. As a closed-loop power converter, it modulates three-phase mains power to provide adjustable voltage and frequency to induction or permanent-magnet motors. In automated machinery, this drive regulates motor speed, limits inrush current, and enables energy-saving control of pumps, conveyors, and fan systems. Its closed-loop operation also allows the connected motor to respond accurately to changing process demands and commanded speed adjustments.
Its motor output is rated at 5.5 kW, indicating the maximum continuous power the inverter can deliver under nominal conditions. This output corresponds to 7.5 HP in imperial units. The input section accepts power from 200–240 V AC three-phase networks, draws up to 22 A, and supplies the motor with a continuous current of 24.2 A. Short-term overload current reaches 38.7 A, allowing the drive to accelerate high-inertia loads without nuisance trips. Its displacement power factor remains above 0.98, while the true power factor is at least 0.9, supporting efficient use of the mains supply. These power-factor values apply during operation on the supported three-phase input network.
At 230 V and full load, apparent power reaches 9.6 kVA, while the internal switching devices dissipate 239 W as heat at the specified efficiency of 0.96. The built-in brake chopper engages at 390 V DC to route regenerated energy to an external resistor, and the protective logic issues an overvoltage alarm at 410 V DC. A separate warning activates when the DC link rises to 405 V DC, prompting inspection of the supply balance. The design limits power-up events to two per minute to protect the capacitors from excessive charging cycles. Installation guidelines permit shielded motor cables up to 50 m long or unshielded cables up to 75 m long without additional output filters or reactors. Control terminals provide a 12-bit analog output for external transducers, allowing process signals to be sent to compatible monitoring or control equipment.