The Danfoss FC-301P5K5T2134L2629 is part of the VLT FC 301 Automation Drives series and has a power rating of 5.5 kW with a 7.5 horsepower output. This three phase drive operates with a mains voltage of 200 to 240 VAC and features a supply frequency of 50/60 Hz. It provides high overload output current of 24.2 Amps and supports output frequencies up to 590 Hz.
Internal Product Review
The FC-301P5K5T2134L2629 is a Danfoss VLT FC 301 automation drive rated at 5.5 kW for 200–240 VAC service. A measured efficiency of 0.96 and a true power factor of at least 0.9 make the design especially attractive for energy-conscious motion applications. A 160% overload capacity for 1 minute per 10 minutes supports demanding duty cycles and highlights strong drive performance.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301P5K5T2134L2629 is an AC variable-frequency drive manufactured by Danfoss for the VLT FC 301 Automation Drives series. It modulates three-phase power so controllers can vary motor speed in conveyors, pumps, and general process equipment. This variable-speed operation can reduce energy use and provide tighter motion control in industrial automation applications.
The drive delivers a continuous output of 5.5 kW, equivalent to 7.5 HP, making it suitable for medium-duty induction motor applications. It accepts a mains supply of 200 to 240 VAC at 50/60 Hz ±5% and is intended for three-phase power networks, allowing balanced current draw across all lines. Within these limits, the inverter can generate an output frequency from 0 to 590 Hz and scale its output voltage from 0 to 100% of the incoming line voltage. A flux-mode range from 0 to 300 Hz is available for sensorless vector control. The maximum allowable phase imbalance is 3%, which helps prevent uneven loading across the rectifier legs. No more than two power-ups per minute are permitted to limit stress on the capacitors. The true power factor is at least 0.9, reducing reactive current demand from the connected supply. An overvoltage alarm activates when the DC link reaches 410 V, protecting internal power components and helping the drive respond to excessive bus voltage.
For transient loads, the high-overload class permits 160% for one minute in every 10 minutes. The corresponding overload currents are 22 A at the input and 24.2 A at the inverter output. During this overload period, thermal dissipation reaches 239 W, so the enclosure must provide enough ventilation to remove the additional heat. The drive has an efficiency of 0.96 at rated current, which limits continuous power loss and reduces cabinet temperature rise. Its adjustable output characteristics allow the connected motor to follow changing torque and speed demands in process equipment without direct operation from fixed-frequency mains power.