The Danfoss FC-301P4K0T4134L2984 is part of the VLT FC 301 Automation Drives series, supporting a rated power of 4.0 kW and a rated horsepower of 5.0 hp. It operates on three phase power with a mains voltage range of 380 to 480 VAC and features an output current of 10 A for 380–440 V. This drive provides four digital inputs, an analog output range of 0/4 to 20 mA, and operates at an efficiency of 0.97.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-301P4K0T4134L2984 is an AC variable frequency drive manufactured by Danfoss for the VLT FC 301 Automation Drives series. As a three-phase inverter, it converts constant-frequency mains power into a controlled electrical output. This output allows PLCs and standalone controllers to adjust induction motor speed, torque, and direction in conveyors, pumps, and other automated plant equipment.
Designed for 380–480 VAC networks, the drive operates at a nominal supply frequency of 50/60 Hz with a ±5% tolerance. At 400 V, the rectifier draws an apparent power of 6.9 kVA, and the inverter stage can continuously supply 10 A to the motor. The output frequency is adjustable from 0–590 Hz, supporting low-speed torque and operation above synchronous speed. Overall efficiency reaches 0.97, which helps limit electrical losses during operation. Four digital inputs accept run commands or preset selections, while an analog output with a range of 0/4–20 mA provides process feedback. The unit tolerates a maximum input current of 9.0 A on 380–440 V lines and supplies an output voltage ranging from 0% to 100% of the line voltage. Its mechanical output is rated at 4.0 kW for connected machinery.
The motor output corresponds to 5.0 hp, making the drive suitable for mid-power applications such as medium centrifuges or blower systems. Internal switching devices dissipate 124 W, so panel ventilation must accommodate this continuous heat load. Motor leads can extend up to 50 m with shielded cable or 75 m with unshielded cable, supporting installations in which the cabinet is located away from the motor. A Form C relay rated for 240 VAC at 2 A can provide an alarm or run indication. The power stage uses a three-phase topology, and the internal control board uses the 301 series architecture.